Design and Performance of a Planar Array Infrared Spectrograph that Operates in the 3400 to 2000 cm-1 Region

نویسنده

  • JOHN F. RABOLT
چکیده

A prototype, no-moving-parts, plane array infrared spectrograph (PA-IR) capable of routine spectral acquisition in the 3400 to 2000 cm21 region has been constructed. The instrument includes a continuous source, Czerney–Turner type monochromator system and an infrared camera that incorporates a 320 3 256 pixel InSb focal plane array detector cooled with liquid nitrogen. PA-IR spectra (;3400 to 2550 cm21) of polystyrene (PS) and poly(ethylene naphthalate) (PEN) Ž lms have been obtained at a resolution of ;8 cm21 with excellent signal-to-noise ratios (SNR). Peak-to-peak noise levels of ;1 3 1023 absorbance units are observed for single acquisition spectra with 1.5 ms integration times and 17 ms total acquisition times. Integration times as low as 10 ms are possible (with good SNR); however, data acquisition is limited by the frame rate (60 frames/s) of the software acquisition package currently used. In this work, an apertured image of the source is displayed over ;20 rows of the array and the expected square root improvement in SNR is observed when multiple rows and/or frames are averaged. We have also shown that a square root improvement in SNR continues to occur with further signal averaging, providing noise levels as low as 1.5 3 1025 absorbance units. Several additional advantages and options associated with the PA-IR method are discussed, including time-resolved spectroscopy, real-time monitoring, and spectroscopic mapping.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.

A no-moving-part planar array infrared spectrograph (PA-IR) equipped with a 256 x 256 mercury cadmium telluride (MCT) focal plane array has been designed and constructed. The performance of the instrument, whose frequency range extends from 2000-975 cm(-1), has been assessed in terms of resolution, bandwidth, and signal-to-noise ratio. The PA-IR spectrograph is able to record spectra with an 8....

متن کامل

شناسائی کانی‌ها به روش طیف‌سنجی در ناحیه‌ی پرتوهای فروسرخ میانی ) (بررسی موردی: کائولینیت و کربنات‌ها)(MW-IR

Infrared spectroscopy (IR) is a powerful tool to decipher the molecular groups in the minerals. This technique of detection, using atomic vibrations of molecules, that is identified through a process of absorption, makes possible the necessary mechanisms of phase analysis of minerals. In this paper, after a brief description of infrared spectroscopy, two groups of minerals will be explained by ...

متن کامل

A Thinning Method of Linear And Planar Array Antennas To Reduce SLL of Radiation Pattern By GWO And ICA Algorithms

In the recent years, the optimization techniques using evolutionary algorithms have been widely used to solve electromagnetic problems. These algorithms use thinning the antenna arrays with the aim of reducing the complexity and thus achieving the optimal solution and decreasing the side lobe level. To obtain the optimal solution, thinning is performed by removing some elements in an array thro...

متن کامل

New developments in planar array infrared spectroscopy.

A planar array infrared (PA-IR) spectrograph offers several advantages over other infrared approaches, including high acquisition rate and sensitivity. However, it suffers from some important drawbacks, such as a limited spectral range and a significant curvature of the recorded spectral images, which still need to be addressed. In this article, we present new developments in PA-IR spectroscopy...

متن کامل

Phoenix: Operation and Performance of a Cryogenic High-resolution 1 { 5 Micron Infrared Spectrograph

At the 1998 SPIE meeting we described a cryogenic, high-resolution spectrograph (Phoenix) for use in the 1 { 5 m region. At that time Phoenix had been used at Kitt Peak for about a year. In the intervening two years we have worked extensively with the instrument and have modiied a few aspects of the design to bring the operational characteristics more closely into agreement with the original sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009