Scintigraphic Imaging with Tantalum-17S and the Anger Scintillation Camera: Concise Communication

نویسندگان

  • B. Leonard Holman
  • Robert E. Zimmerman
  • Louis V. Bifolck
  • Rudi D. Neirinckx
چکیده

Tantalum-178 is a short-lived radionuclide (Tm = 9.3 min.) and emits primarily 56to 64-keV characteristic x-rays. We have determined the imaging characteristics with this radionuclide and a large-field-of-view Anger camera. With a pinhole collimator, good spatial resolution is possible with Ta-178, although the image quality is superior with Tc-99m under comparable conditions. Spatial resolution with parallelhole or converging collimators was much less satisfactory with Ta-178 because of septal penetration by high-energy photons. Pulmonary perfusion and liver-spleen images of excellent quality were obtained in the rabbit using the pinhole collimator and Ta-178-labeled agents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scintigraphic imaging with tantalum-178 and the Anger scintillation camera: concise communication.

Tantalum-178 is a short-liver radionuclide (T 1/2 = 9.3 min.) and emits primarily 56- to 64-keV characteristic x-rays. We have determined the imaging characteristics with this radionuclide and a large-field-of-view Anger camera. With a pinhole collimator, good spatial resolution is possible with Ta-178, although the image quality is superior with Tc-99m under comparable conditions. Spatial reso...

متن کامل

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Quantitative Evaluation of Scintillation Camera Imaging Characteristics of Isotopes Used in Liver Radioembolization

BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...

متن کامل

A Computer Service for Analyzing Clinical Scintigraphic Data

A scintillation camera and computer assembly is described whereby clinical and research scintigraphic data can be processed by a computer through a videotape transfer system. This assembly can provide a full computer capability to hospital clinics which are not equipped with a computer but still require convenient and rapid data analysis. Tomographic and anatomical marker data can also be acces...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008