An experimental comparison of the relative benefits of work and torque assistance in ankle exoskeletons.

نویسندگان

  • Rachel W Jackson
  • Steven H Collins
چکیده

Techniques proposed for assisting locomotion with exoskeletons have often included a combination of active work input and passive torque support, but the physiological effects of different assistance techniques remain unclear. We performed an experiment to study the independent effects of net exoskeleton work and average exoskeleton torque on human locomotion. Subjects wore a unilateral ankle exoskeleton and walked on a treadmill at 1.25 m·s(-1) while net exoskeleton work rate was systematically varied from -0.054 to 0.25 J·kg(-1)·s(-1), with constant (0.12 N·m·kg(-1)) average exoskeleton torque, and while average exoskeleton torque was systematically varied from approximately zero to 0.18 N·m·kg(-1), with approximately zero net exoskeleton work. We measured metabolic rate, center-of-mass mechanics, joint mechanics, and muscle activity. Both techniques reduced effort-related measures at the assisted ankle, but this form of work input reduced metabolic cost (-17% with maximum net work input) while this form of torque support increased metabolic cost (+13% with maximum average torque). Disparate effects on metabolic rate seem to be due to cascading effects on whole body coordination, particularly related to assisted ankle muscle dynamics and the effects of trailing ankle behavior on leading leg mechanics during double support. It would be difficult to predict these results using simple walking models without muscles or musculoskeletal models that assume fixed kinematics or kinetics. Data from this experiment can be used to improve predictive models of human neuromuscular adaptation and guide the design of assistive devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Musculoskeletal modelling deconstructs the paradoxical effects of elastic ankle exoskeletons on plantar-flexor mechanics and energetics during hopping.

Experiments have shown that elastic ankle exoskeletons can be used to reduce ankle joint and plantar-flexor muscle loading when hopping in place and, in turn, reduce metabolic energy consumption. However, recent experimental work has shown that such exoskeletons cause less favourable soleus (SO) muscle-tendon mechanics than is observed during normal hopping, which might limit the capacity of th...

متن کامل

Comparison of Torque Controllers for an Ankle Exoskeleton with a Series Elastic Actuator Driven by a Uni-directional Bowden Cable during Walking

Exoskeletons have been used for human performance restoration and enhancement for many years. Due to the dynamic nature of human locomotion, torque control is widely used in lower-limb exoskeleton assistance during stance phases of walking. In these systems, series-elastic actuators (SEA) are commonly used to provide low error torque tracking in the presence of unknown and changing human dynami...

متن کامل

Design of a Comfortable Pure Moment Knee Exoskeleton

Lower-limb exoskeletons have the potential to enhance rehabilitation [1], assist in walking with gait impairments [2], reduce the metabolic cost of normal [3] and load-bearing walking [4], improve stability [5] and probe interesting questions about human locomotion [6]. The ankle produces larger peak torques and performs more positive work than either the hip or the knee during locomotion [7], ...

متن کامل

Muscle recruitment and coordination with an ankle exoskeleton.

Exoskeletons have the potential to assist and augment human performance. Understanding how users adapt their movement and neuromuscular control in response to external assistance is important to inform the design of these devices. The aim of this research was to evaluate changes in muscle recruitment and coordination for ten unimpaired individuals walking with an ankle exoskeleton. We evaluated...

متن کامل

Human-in-the-loop optimization of exoskeleton assistance during walking.

Exoskeletons and active prostheses promise to enhance human mobility, but few have succeeded. Optimizing device characteristics on the basis of measured human performance could lead to improved designs. We have developed a method for identifying the exoskeleton assistance that minimizes human energy cost during walking. Optimized torque patterns from an exoskeleton worn on one ankle reduced met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 119 5  شماره 

صفحات  -

تاریخ انتشار 2015