Pico2 Monitoring of Transferred Jejunum Perfusion Using an Air Tonometry Technique After Hypopharyngeal Cancer Surgery

نویسندگان

  • Hiroyuki Ozawa
  • Yorihisa Imanishi
  • Fumihiro Ito
  • Yoshihiro Watanabe
  • Takashi Kato
  • Hideo Nameki
  • Kiyoshi Isobe
  • Kaoru Ogawa
  • Maria Kapritsou.
چکیده

This study aimed to investigate the usefulness of intraluminal PCO2 (PiCO2) monitoring by air tonometry for the assessment of the vascular condition of the transferred jejunum after surgery for hypopharyngeal cancer.PiCO2 in the transplanted jejunum of 24 patients was monitored using air tonometry after radical surgery for hypopharyngeal cancer from 2003 to 2010.All but 1 patient, who removed the catheter before monitoring began, were monitored safely. PiCO2 in the transferred jejunum correlated with arterial PCO2 (PaCO2) that was measured concurrently, and dissociation of PiCO2 from PaCO2 was observed in cases with vascular complication. In those cases without postoperative vascular complication, the PiCO2 value gradually increased for 3 hours but then decreased by 12 hours after surgery. Three patients experienced major vascular complication. All 3 patients had continuous elevation of PiCO2 >100 mm Hg, although vascular flow in 1 patient recovered by removal of a venous thrombosis and reanastomosis of the vein 7.5 hours after surgery. Four other patients who experienced elevation of PiCO2 had their skin suture released for decompression of their neck wound, resulting in a decrease in PiCO2 after treatment.The current results demonstrated that continuous monitoring of PiCO2 by air tonometry accurately reflects the vascular condition of the transferred jejunum, and this method is one of the best options for postoperative monitoring of jejunum blood perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Salvage surgery for recurrent carcinoma of the hypopharynx and reconstruction using jejunal free tissue transfer and pectoralis major muscle pedicled flap.

OBJECTIVE To evaluate patients undergoing salvage surgery after recurrent squamous cell carcinoma of the hypopharynx. DESIGN Retrospective analysis. SETTING All patients underwent surgery and follow-up evaluations at the Medical University of Vienna. The departments of Surgery and Otorhinolaryngology carried out patient care and analysis of data. PATIENTS A total of 8 consecutive patients...

متن کامل

Gastric tonometry: in vivo comparison of saline and air tonometry in patients with cardiogenic shock.

Measurement of gastric intramucosal pH (pHi) has been advocated to assess gastric perfusion. Regional PCO2 (rPCO2) values are measured using saline tonometry (rsPCO2) and more recently using air tonometry (raPCO2). We compared 237 measurements of saline and air tonometry in 19 consecutive, severely ill patients (mean age 59 (range 31-76) yr, 19 males, APACHE II 22 +/- 7) with cardiogenic shock....

متن کامل

Three-dimensional reconstruction of supraglottic structures after partial pharyngolaryngectomy for hypopharyngeal cancer.

OBJECTIVE Larynx-preserving surgery is frequently performed for advanced hypopharyngeal cancer involving the larynx. However, reconstruction after partial pharyngolaryngectomy (PPL) remains a challenging problem because of the high risk of postoperative aspiration. In this report, we describe our new three-dimensional method for reconstructing supraglottic structures with a radial forearm flap....

متن کامل

Characteristics of time-dependent PCO2 tonometry in the normal human stomach.

Factors that affect PCO2 measurement in balloon saline during gastrointestinal tonometry are unclear. They include carbon dioxide diffusion rate, correction factors for calculation of equilibrium PCO2 from measurements at saline dwell times that are shorter than needed for full equilibration, role of blood-gas analyser bias during ex vivo PCO2 measurements in saline, and normal values for intra...

متن کامل

Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry

Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thicknes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015