Contrast-enhanced transcranial color-coded real-time sonography. Results of a phase-two study.

نویسندگان

  • U Bogdahn
  • G Becker
  • R Schlief
  • J Reddig
  • W Hassel
چکیده

BACKGROUND AND PURPOSE Transcranial color-coded real-time sonography has been developed as a promising new bedside procedure to monitor central nervous system parenchymal and vascular pathology; the present study was designed to investigate the potential role of galactose microparticles (SH U 508 A) as a new ultrasound contrast-enhancing agent for transcranial sonography. METHODS Ten patients (four women and six men, 24-63 years of age) with a broad spectrum of central nervous system pathology were investigated by transcranial color-coded real-time sonography in a phase-two clinical study. After conventional ultrasound examination, all patients received a maximum of six injections of 10 ml with 200, 300, or 400 mg/mL SH U 508 A. The intracranial vessels were scanned by color flow imaging in the axial and coronal planes through a transtemporal acoustic bone window; in addition, the vertebrobasilar system was followed through the foramen magnum. RESULTS SH U 508 A was well tolerated without side effects. In axial and coronal scans, the application of SH U 508 A resulted in detection of peripheral branches of the anterior, middle, and posterior cerebral arteries, as well as the posterior communicating and superior cerebellar arteries. In addition, the deep cerebral veins (i.e., inferior sagittal sinus, internal cerebral veins, great cerebral vein of Galen, straight sinus, and the confluence sinuum) were revealed. The transforaminal approach led to detection of the main infratentorial branches (anterior inferior, posterior inferior, and superior cerebellar arteries). One patient could not be insonated without contrast, but after SH U 508 A the trunks of the large intracranial arteries were detected. No obvious changes in the ultrasound pattern of the central nervous system parenchyma were observed. CONCLUSIONS These preliminary data indicate that the use of a transpulmonary ultrasound contrast agent (SH U 508 A) may substantially broaden the spectrum and potential diagnostic utility of transcranial ultrasound by allowing detection of supratentorial peripheral central nervous system arteries, deep cerebral veins, and (through the foramen magnum) the entire vertebrobasilar system, including the cerebellar arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

Contrast-enhanced transcranial color-coded sonography in acute hemispheric brain infarction.

PURPOSE The aim of the present study was to investigate the diagnostic potential of contrast-enhanced transcranial color-coded real-time sonography (CE-TCCS) in otherwise ultrasound-refractory acute stroke patients with an ischemia in the territory of the middle cerebral artery (MCA). Furthermore, correlations of CE-TCCS findings with clinical, angiographic, and CT results were investigated. ...

متن کامل

Relationship between findings of conventional and contrast-enhanced transcranial color-coded real-time sonography and angiography in patients with basilar artery occlusion.

BACKGROUND AND PURPOSE Contrast-enhanced transcranial color-coded real-time sonography (TCCS) is a promising tool for the evaluation of brain circulation. The purpose of the present study was to assess the diagnostic ability of conventional and contrast-enhanced TCCS in patients with acute stroke and basilar artery occlusion and to compare the findings with those of angiography. METHODS We pr...

متن کامل

Consensus recommendations for transcranial color-coded duplex sonography for the assessment of intracranial arteries in clinical trials on acute stroke.

BACKGROUND AND PURPOSE Transcranial color-coded duplex sonography has become a standard diagnostic technique to assess the intracranial arterial status in acute stroke. It is increasingly used for the evaluation of prognosis and the success of revascularization in multicenter trials. The aim of this international consensus procedure was to develop recommendations on the methodology and document...

متن کامل

Intracranial aneurysms treated with endovascular coils: detection of recurrences using unenhanced and contrast-enhanced transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE Because neck recurrence after endovascular treatment of intracranial aneurysms (IAs) is not uncommon, surveillance to assess long-term stability of occlusion is clearly important. This study evaluated unenhanced and contrast-enhanced transcranial color-coded duplex sonography (TCCS) in detecting refilling of IAs treated with detachable coils. METHODS Patients with coile...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 1993