Intraluminal projection of descending thoracic aorta and intraaortic balloon pump catheter examined by transesophageal echocardiography in patients undergoing coronary artery bypass surgery.

نویسندگان

  • K Orihashi
  • Y Oka
چکیده

The thoracic descending aorta (DTA) was examined in 57 patients undergoing coronary artery bypass grafting (41 men and 16 women: 63.0 +/- 10.6 years old) using two-dimensional transesophageal echocardiography. An intraaortic balloon pump (IABP) was instituted in ten patients. A short-axis view of DTA was examined for intraluminal projection from the diaphragm level to the aortic arch level. In a frozen-frame image, the area and the height of the projection at each clockwise direction was measured. Four patients with preoperative insertion of an IABP catheter were excluded from the analysis. Seventy projections were found in 40 of 53 patients (75.5%), most frequently found at the 3 to 6 o'clock position. The tip of the IABP catheter was also located in the area between 3 and 6 o'clock of the aortic lumen in 6 of 10 patients. In one case, the area of projection was reduced from 1.1 cm2 to 0.7 cm2. In two of four patients with preoperative institution of an IABP catheter, projections were found near the catheter tip. Both intraluminal projections and IABP catheter tip were most commonly located in the same region of the DTA, suggesting a possible dislodging of the projection while advancing the catheter. This was demonstrated in one case. The catheter tip may damage the aortic intima and/or cause a formation of abnormal projection. We conclude that intraoperative examination of DTA in addition to routine monitoring can provide useful information which is helpful for minimizing complications at the time of insertion of an IABP catheter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of Possible Embolus Following Intra Aortic Balloon Counterpulsation (IABP) Insertion by Transesophageal Echocardiography ( TEE )

Severe atherosclerosis of the descending aorta is directly related to atheroembolic events. Transesophageal echocardiography (TEE) is a sensitive technique for evaluating such atheroma plaques of the thoracic aorta which may predict the risk of emboli. We describe a patient with severe intraluminal aortic atherosclerotic plaques detected by TEE while positioning an Intraaortic Balloon Counterpu...

متن کامل

Stroke after intraaortic balloon counterpulsation associated with mobile atheroma in thoracic aorta diagnosed using transesophageal echocardiography.

We describe a patient who developed embolic stroke after coronary artery bypass grafting (CABG) associated with intraaortic balloon pump (IABP) insertion. Intraoperative transesophageal echocardiography (TEE) revealed marked irregular mass and disruption of the intimal surface of the thoracic aorta with overlying shaggy echogenic material on the intimal surface of the descending thoracic aortic...

متن کامل

Influence of timing of intraaortic balloon placement in cardiac surgical patients.

OBJECTIVE The study objective was to evaluate the association between timing of intraaortic balloon pump insertion and outcomes in patients undergoing cardiac surgery. METHODS All patients aged 18 years or more who underwent coronary artery bypass surgery, cardiac valve surgery, or thoracic aortic surgery between January 2002 and December 2007 were included. Data were obtained from cardiac su...

متن کامل

Descending aortic pulsed wave Doppler can predict changes in cardiac output during off-pump coronary artery bypass surgery.

Retraction and stabilization of the heart can induce rapid and large changes in the hemodynamic state during off-pump coronary artery bypass graft surgery (OPCABG). We aimed to determine if Doppler measurement of flow in the descending artery with transesophageal echocardiography (TEE) can provide a beat-to-beat assessment of changes in cardiac output (CO) in 26 OPCABG patients. Simultaneous me...

متن کامل

Positioning an intraaortic balloon pump using intraoperative transesophageal echocardiogram guidance.

A 72-year-old man with an ejection fraction of 25% is scheduled to undergo elective coronary artery bypass graft using cardiopulmonary bypass. Because of the high-risk nature of the operation, the surgeon wants to insert an intraaortic balloon pump (IABP) before initiating cardiopulmonary bypass. An intraoperative transesophageal echocardiogram (TEE) is requested to ensure correct placement.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hiroshima journal of medical sciences

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 1991