Interference with hemoglobin A(1C) determination by the hemoglobin variant Shelby.
نویسندگان
چکیده
Hemoglobin variant carrier status was found in a 46-year-old African American man following detection of a falsely elevated hemoglobin A1c (HbA1c) by ionexchange high-performance liquid chromatography (HPLC, VARIANT A1c, Bio-Rad Laboratories, Hercules, CA). Additional analysis of the hemoglobin variant using the Beta Thal Short program (Bio-Rad) revealed an unknown peak with a retention time of 4.84 minutes and a proportion of 26.3%. No mass shift in alpha-globin or beta-globin proteins was observed by mass spectrometry. DNA sequencing revealed a missense mutation in 1 beta-globin allele corresponding to the hemoglobin Shelby trait. The patient was asymptomatic with a normal hemoglobin value of 13.6 g/dL (136 g/L) but had increased target cells on a peripheral blood smear. An alternative method for HbA1c determination using boronate-affinity HPLC provided a value of 3.9% (0.04; reference range, 4.0%-6.9% [0.04-0.07]), more consistent with the patient's recent blood glucose values in the normal range.
منابع مشابه
Effects of Coenzyme Q10 on Hemoglobin A1C, Serum Urea and Creatinine in Alloxan-Induced Type 1 Diabetic Rats
Coenzyme Q 10 is a natural antioxidant and free radicals scavenger. In the present study, we examined effect of coenzyme Q 10 on hemoglobin A 1C , serum urea and creatinine in alloxan-induced Type 1 diabetic rats. Thirty Sprage-Dawley male rats were divided into three groups randomly; group one as control, group two diabetic untreatment, and group three treatments with coenzyme Q ...
متن کاملSilent haemoglobin variants and determination of HbA(1c) with the HPLC Bio-Rad Variant II.
AIMS To evaluate the determination of HbA(1c) with an automated high performance liquid chromatography (HPLC) method in patients with clinically silent haemoglobin variants. METHODS HbA(1c) values were determined with the ion exchange HPL Bio-Rad Variant II using the high resolution beta thalassaemia programme in patients with silent haemoglobin variants, namely: Hb Graz, Hb Sherwood Forest, ...
متن کاملIncidental findings of variant hemoglobin during hemoglobin A(1c) testing.
A variant hemoglobin fraction may be an incidental finding during HbA(1c) analysis using the G8 Tosoh HPLC analyzer, but it is unclear if the retention times and fraction patterns can reliably predict the findings of a high-performance liquid chromatography (HPLC) β-thalassemia program (Bio Rad Variant II analyzer). We chose 100 samples sent for HbA(1c) determinations (G8 Tosoh) with an inciden...
متن کاملHemoglobin Daneshgah-Tehran (HBA1:c.218A>G p.His72Arg): a Rare α1-Globin Variant from Iran
There are more than 400 different variations on α-globin protein, and most of them are not associated with noticeable clinical manifestation. Hemoglobin (Hb) is an oxygen-transporting protein and Hb Daneshgah- Tehran is an α-globin variant that for the first time was reported from Iran in a case with normal haematological indices. The capillary electrophoresis of an 8-year- old-girl with normal...
متن کاملHaemoglobin J-Baltimore can be detected by HbA1c electropherogram but with underestimated HbA1c value
Glycated haemoglobin (HbA(1c)) is considered the gold standard for assessing diabetes compensation and treatment. In addition, fortuitous detection of haemoglobin variants during HbA1c measurement is not rare. Recently, two publications reported different conclusions on accuracy of HbA(1c) value using capillary electrophoresis method in presence of haemoglobin J-Baltimore (HbJ). Here we describ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of clinical pathology
دوره 128 3 شماره
صفحات -
تاریخ انتشار 2007