Finite element method based stress analysis of zone I and zone II sacral fractures.

نویسندگان

  • Hakan Bozkuş
  • Murat Hanci
  • M Emin Sünbüloğlu
  • M Ali Tunali
  • S Ergun Bozdağ
  • Onder Aydingöz
  • Alaattin Arpaci
چکیده

BACKGROUND Sacral bone fractures after direct traumas such as gunshot wounds and blunt sacral traumas are rarely, whereas those occurring after indirect traumas with vertical shear mechanisms ( car accidents or falls) are more frequently seen. METHODS A cadaver sacrum was modelled 3-dimensionally using finite element software. Left sacroiliac joint was modeled to simulate a 75- kg man falling on one leg from a height of 5 meters. An impact load of 10 kN was transferred to the sacrum via intervertebral disc surface and two facets. Von Mises equivalent stress distribution was estimated. RESULTS Von Mises stress distribution was calculated for sacral ala (430 MPa), S1 pedicle (225 MPa), and S1 lamina (35 MPa). Stress values were 200 Mpa, 130 Mpa, 105 Mpa, and 55 MPa on ventrolateral, dorsomedial, ventromedial and dorsolateral sides of S1 foramen respectively. Vertical shear injury caused stress distribution to concentrate at sacral ala and S1 pedicle (zone I). Local stress distribution around S1 foramen is concentrated ventrolaterally CONCLUSION High incidence of zone I sacral fractures and low incidence of neurological deficits could be explained by concentration of stress at sacral ala. Zone II fractures might be due to by transfer of triggered stresses from sacral ala and S1 pedicle to ventrolateral side of S1 foramen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT-Guided Screw Fixation of Vertical Sacral Fractures in Local Anaesthesia Using a Standard CT CT-kontrollierte Schraubenosteosynthese von vertikalen Frakturen des hinteren Beckenringes in Lokalanästhesie

Purpose: To evaluate time efficiency, radiation dose, precision and complications of percutaneous iliosacral screw placement under CT-guidance in local anaesthesia. Material and Methods: Retrospective analysis of 143 interventions in 135 patients during a period of 42 months. Implant failures could be evaluated in 85/182 screws and bony healing or refracturing in 46/182 screws. Results: A total...

متن کامل

Crack Behavior of the Aluminum Alloy 2024 Under Fretting Conditions

The initial stage of fretting fatigue crack growth is significantly influenced by tangential force induced by fretting action along the contact surface where a mixed-mode crack growth is involved. Fretting crack behavior of aluminum alloy 2024 was studied, taking into account the problem of contact asperities. Finite element was used for the determination of the stress field near the contact su...

متن کامل

مقایسه روش آنالیز ایزوژئومتریک و روش اجزای محدود توسعه ‌یافته در مدل‌سازی ناپیوستگی و محاسبه فاکتور شدت تنش

This study shows how to create different types of crack and discontinuities by using isogeometric analysis approach (IGA) and extended finite element method (XFEM). In this contribution, two unique features of isogeometric analysis approach are utilized to create discontinuous zones. Discontinuities consist of crack and cohesive zone. In isogeometric analysis method NURBS is used to approximate...

متن کامل

Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis.

PURPOSE Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS. METHODS Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded ve...

متن کامل

Using the Finite Element Analysis Method to Study the 3-point Bending Test for the Characterization of the Adherence

An elastic finite element analysis was conducted to evaluate the stress distribution in the initiation zone of the adhesive rupture during the 3-point bending test. This test is used to measure the adherence between a polyepoxy adhesive and aluminum alloy with different surface treatments. The purpose is to compare, in the high stress concentration areas, the stress fields calculated using fini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2005