Performance of a full facepiece, air-purifying respirator against lead aerosols in a workplace environment.

نویسندگان

  • Larry Janssen
  • Jeanne Bidwell
چکیده

This study evaluated workplace performance of a full facepiece, negative pressure, air-purifying respirator with P100 filters in a lead refining plant. Air samples for lead were collected inside and outside the respirators worn by workers who were properly trained and quantitatively fit tested. Trained observers assisted in the study to ensure sample validity. Three to four pairs of air samples per day were collected from each worker for a total of 52 valid sample sets. Lead was found on all the outside samples, and concentrations were below the detection limit for all but one of the inside samples. The single measurable inside sample yielded a workplace protection factor (WPF) of 297. WPFs for the rest of the samples were estimated using the assumption that lead was present at the detection limit for the in-facepiece samples. Calculated WPFs were rounded down to the nearest 100 then subjected to a rank and percentile function. The 5th percentile WPF was approximately 900 using this approach. These WPFs exceed the assigned protection factor (APF) of 50 for this respirator class recommended by the National Institute for Occupational Safety and Health and listed by the Occupational Safety and Health Administration. These results support the APF of 50 for this respirator and indicate the respirator provided adequate protection as used in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of respirator filters using quality factor in Korea.

A respirator filter of good quality has not only high aerosol collection efficiency but also low air resistance. "Quality factor", which is expressed with aerosol penetration and pressure drop, can be used to rank the performance of respirator filters within the same category. This study focuses on evaluating several respirator filters which are widely used in Korea using quality factor. Two me...

متن کامل

تعیین طول عمر کارتریج های ماسکهای تنفسی با استفاده از یک روش ساده و کاربردی: مطالعه موردی در یک صنعت خودروسازی

  Background and aims: For ensuring about proper performance of air-purifying respirators in providing protection against workplace contaminants, it is necessary to change the respirator cartridges before the end of their service life. The aim of this study was determination of service life of organic vapor cartridges using a simple and practical method in a spray painting booth of a car manufa...

متن کامل

Comparison of nanoparticle filtration performance of NIOSH-approved and CE-marked particulate filtering facepiece respirators.

The National Institute for Occupational Safety and Health (NIOSH) and European Norms (ENs) employ different test protocols for evaluation of air-purifying particulate respirators commonly referred to as filtering facepiece respirators (FFR). The relative performance of the NIOSH-approved and EN-certified 'Conformité Européen' (CE)-marked FFR is not well studied. NIOSH requires a minimum of 95 a...

متن کامل

Evaluation of N95 Filtering Facepiece Respirators Challenged with Engineered Nanoparticles

NIOSH-certified respirators, including N95 respirators, are recommended when engineering and administrative controls do not adequately prevent exposures to airborne nanomaterials. Laboratory evaluations of filtering efficiency using standard test aerosols have been reported in the literature, but there is no information on penetration of engineered nanoparticles (1–100 nm) for N95 filtering fac...

متن کامل

Challenge of N95 filtering facepiece respirators with viable H1N1 influenza aerosols.

OBJECTIVE. Specification of appropriate personal protective equipment for respiratory protection against influenza is somewhat controversial. In a clinical environment, N95 filtering facepiece respirators (FFRs) are often recommended for respiratory protection against infectious aerosols. This study evaluates the ability of N95 FFRs to capture viable H1N1 influenza aerosols. METHODs. Five N95 F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2007