Vascular rupture during angioplasty of hemodialysis raft-related stenoses.

نویسندگان

  • J N Pappas
  • T M Vesely
چکیده

PURPOSE To retrospectively determine the incidence and outcome of angioplasty-induced ruptures that occurred during treatment of hemodialysis graft-related stenoses. MATERIALS AND METHODS During a five year period 1222 patients with dysfunctional or thrombosed polytetrafluoroethylene (PTFE) hemodialysis grafts underwent angioplasty procedures at our institution. Angioplasty-induced vascular ruptures occurred in 24 (2.0%) patients. The locations of these ruptures were: basilic vein (10), venous anastomosis (7), cephalic vein (5), brachial vein (1) and intragraft (1). The mean length of the treated stenoses was 2.4 centimeters. RESULTS Manual compression was used to treat the vascular rupture in ten patients. One patient was treated with endovascular balloon tamponade and one patient underwent stenting of the rupture site. Despite the rupture, 15 patients had completion of the angioplasty procedure. In nine patients the procedure was abandoned due to persistent stenosis at the rupture site. There were no major complications as a result of these ruptures. Follow-up was available in ten of these patients. All ten underwent at least one successful hemodialysis treatment. In five of these patients the hemodialysis graft failed within 30 days after the rupture. The mean primary patency following rupture in the ten patients with follow-up was 87.5 days (range 5 - 225 days). CONCLUSION The incidence of angioplasty-induced vascular rupture of hemodialysis-related stenoses is low and despite the injury, the majority (62%) of procedures can be completed. However, in our experience the long-term patency of the vascular access was suboptimal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angioplasty balloon inflation pressures during treatment of hemodialysis graft-related stenoses.

PURPOSE This two-part prospective investigation was designed to determine the balloon inflation pressures required to dilate stenoses associated with hemodialysis grafts and evaluate the burst pressures of five different angioplasty balloons. MATERIALS AND METHODS Eighty-nine patients with dysfunctional hemodialysis grafts were enrolled and underwent fistulography. The diagnostic studies reve...

متن کامل

Use of the peripheral cutting balloon to treat hemodialysis-related stenoses.

PURPOSE To compare the effectiveness and safety of use of the peripheral cutting balloon (PCB) versus standard percutaneous transluminal angioplasty (PTA) for the treatment of hemodialysis-related stenoses. MATERIALS AND METHODS This prospective, randomized multicenter clinical trial included 340 patients with stenotic or thrombosed hemodialysis grafts who were randomized to receive treatment...

متن کامل

Use of stents and stent grafts to salvage angioplasty failures in patients with hemodialysis grafts.

To determine the efficacy of using stents and stent grafts for treatment of hemodialysis graft-related stenoses which have failed angioplasty. This retrospective study was composed of 51 patients with polytetrafluoroethylene hemodialysis grafts who underwent angioplasty of a graft-related stenosis but subsequently required insertion of a stent or stent graft. The study group included 40 patient...

متن کامل

Arterial problems associated with dysfunctional hemodialysis grafts: evaluation of patients at high risk for arterial disease.

PURPOSE To retrospectively review the incidence and types of arterial problems associated with dysfunctional hemodialysis grafts in patients who are at high risk for peripheral arterial disease. MATERIALS AND METHODS During the 1-year period from February 2001 to February 2002, 40 patients with polytetrafluoroethylene hemodialysis grafts underwent upper extremity arteriography to evaluate art...

متن کامل

Endovascular Stent Placement of Juxtaanastomotic Stenosis in Native Arteriovenous Fistula After Unsuccessful Balloon Angioplasty

BACKGROUND In hemodialysis patients, the most common problem in arteriovenous fistulas, as the best functional vascular access, is the juxtaanastomotic located lesions. Percutaneous transluminal angioplasty is accepted as the treatment method for juxtanastomotic lesions. OBJECTIVES To assess juxtaanastomotic stent placement after insufficient balloon angioplasty in the treatment of autogenous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of vascular access

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2002