Embolic protection and platelet inhibition during renal artery stenting.

نویسندگان

  • Christopher J Cooper
  • Steven T Haller
  • William Colyer
  • Michael Steffes
  • Mark W Burket
  • William J Thomas
  • Robert Safian
  • Bhagat Reddy
  • Pamela Brewster
  • Mary Ann Ankenbrandt
  • Renu Virmani
  • Eric Dippel
  • Krishna Rocha-Singh
  • Timothy P Murphy
  • David J Kennedy
  • Joseph I Shapiro
  • Ralph D D'Agostino
  • Michael J Pencina
  • Sadik Khuder
چکیده

BACKGROUND Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown. METHODS AND RESULTS One hundred patients undergoing renal artery stenting at 7 centers were randomly assigned to an open-label embolic protection device, Angioguard, or double-blind use of a platelet glycoprotein IIb/IIIa inhibitor, abciximab, in a 2x2 factorial design. The main effects of treatments and their interaction were assessed on percentage change in Modification in Diet in Renal Disease-derived glomerular filtration rate from baseline to 1 month using centrally analyzed creatinine. Filter devices were analyzed for the presence of platelet-rich thrombus. With stenting alone, stenting and embolic protection, and stenting with abciximab alone, glomerular filtration rate declined (P<0.05), but with combination therapy, it did not decline and was superior to the other allocations in the 2x2 design (P<0.01). The main effects of treatment demonstrated no overall improvement in glomerular filtration rate; although abciximab was superior to placebo (0+/-27% versus -10+/-20%; P<0.05), embolic protection was not (-1+/-28% versus -10+/-20%; P=0.08). An interaction was observed between abciximab and embolic protection (P<0.05), favoring combination treatment. Abciximab reduced the occurrence of platelet-rich emboli in the filters from 42% to 7% (P<0.01). CONCLUSIONS Renal artery stenting alone, stenting with embolic protection, and stenting with abciximab were associated with a decline in glomerular filtration rate. An unanticipated interaction between Angioguard and abciximab was seen, with combination therapy better than no treatment or either treatment alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Platelet activation in patients with atherosclerotic renal artery stenosis undergoing stent revascularization.

BACKGROUND AND OBJECTIVES Soluble CD40 ligand (sCD40L) is a marker of platelet activation; whether platelet activation occurs in the setting of renal artery stenosis and stenting is unknown. Additionally, the effect of embolic protection devices and glycoprotein IIb/IIIa inhibitors on platelet activation during renal artery intervention is unknown. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENT...

متن کامل

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.

BACKGROUND Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such ...

متن کامل

An update on herpes virus infections in graft recipients.

percutaneous coronary and carotid interventions. Curr Control Trials Cardiovasc Med 2001; 2: 286–291 11. Angelini A, Reimers B et al. Cerebral protection during carotid artery stenting. Stroke 2002; 33: 456–461 12. Webb JG, Carere RGC, Virmani R et al. Retrieval and analysis of particulate debris after saphenous vein graft intervention. J Am Col Cardiol 1999; 34: 468–475 13. Baim DS, Wahr D, Ge...

متن کامل

Controversies in the management of the renal artery stenosis.

Optimal management of renal artery stenosis has continued to remain elusive. The previous non randomized studies and registry data suggested a benefit of renal artery stenting. However, the recently completed randomized studies comparing renal stenting to medical management failed to show any benefit. These studies had some flaws in their design and methodology. In an appropriately selected pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 117 21  شماره 

صفحات  -

تاریخ انتشار 2008