Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential.

نویسندگان

  • F Avraham Dilmanian
  • Zhong Zhong
  • Tigran Bacarian
  • Helene Benveniste
  • Pantaleo Romanelli
  • Ruiliang Wang
  • Jeremy Welwart
  • Tetsuya Yuasa
  • Eliot M Rosen
  • David J Anschel
چکیده

Studies have shown that x-rays delivered as arrays of parallel microplanar beams (microbeams), 25- to 90-microm thick and spaced 100-300 microm on-center, respectively, spare normal tissues including the central nervous system (CNS) and preferentially damage tumors. However, such thin microbeams can only be produced by synchrotron sources and have other practical limitations to clinical implementation. To approach this problem, we first studied CNS tolerance to much thicker beams. Three of four rats whose spinal cords were exposed transaxially to four 400-Gy, 0.68-mm microbeams, spaced 4 mm, and all four rats irradiated to their brains with large, 170-Gy arrays of such beams spaced 1.36 mm, all observed for 7 months, showed no paralysis or behavioral changes. We then used an interlacing geometry in which two such arrays at a 90-degree angle produced the equivalent of a contiguous beam in the target volume only. By using this approach, we produced 90-, 120-, and 150-Gy 3.4 x 3.4 x 3.4 mm(3) exposures in the rat brain. MRIs performed 6 months later revealed focal damage within the target volume at the 120- and 150-Gy doses but no apparent damage elsewhere at 120 Gy. Monte Carlo calculations indicated a 30-microm dose falloff (80-20%) at the edge of the target, which is much less than the 2- to 5-mm value for conventional radiotherapy and radiosurgery. These findings strongly suggest potential application of interlaced microbeams to treat tumors or to ablate nontumorous abnormalities with minimal damage to surrounding normal tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Precision Radiosurgical Dose Delivery by Interlaced Microbeam Arrays of High-Flux Low-Energy Synchrotron X-Rays

Microbeam Radiation Therapy (MRT) is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very h...

متن کامل

Tolerance of arteries to microplanar X-ray beams.

PURPOSE The purpose is to evaluate effects of a new radiotherapy protocol, microbeam radiation therapy, on the artery wall. In previous studies on animal models, it was shown that capillaries recover well from hectogray doses of X-rays delivered in arrays of narrow (< or = 50 microm) beams with a minimum spacing of 200 microm. Here, short- and long-term effects of comparable microplanar beam co...

متن کامل

Assessment of optical CT as a future QA tool for synchrotron x-ray microbeam therapy.

Synchrotron microbeam radiation therapy (MRT) is an advanced form of radiotherapy for which it is extremely difficult to provide adequate quality assurance. This may delay or limit its clinical uptake, particularly in the paediatric patient populations for whom it could be especially suitable. This study investigates the extent to which new developments in 3D dosimetry using optical computed to...

متن کامل

Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT).

Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy (MRT) are both novel approaches to treat brain tumor and potentially other tumors using synchrotron radiation. Although the techniques differ by their principles, SSRT and MRT share certain common aspects with the possibility of combining their advantages in the future. For MRT, the technique uses highly collimated, qu...

متن کامل

Consider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.

Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 103 25  شماره 

صفحات  -

تاریخ انتشار 2006