Contrast-enhanced magnetic resonance angiography of the cervical vessels: experience with 422 patients.

نویسندگان

  • T Phan
  • J Huston
  • M A Bernstein
  • S J Riederer
  • R D Brown
چکیده

BACKGROUND AND PURPOSE Contrast-enhanced magnetic resonance angiography (CEMRA) permits acquisition of high-spatial-resolution, venous-suppressed, 3D MR angiograms of the cervical carotid and vertebral arteries. In this study, an elliptic centric-view ordering with either MR fluoroscopic triggering or test bolus timing was used. The use of CEMRA of the cervical vessels has changed our clinical practice and is replacing conventional angiography for the evaluation of most carotid and vertebral artery diseases. METHODS We retrospectively reviewed our experience with the use of CEMRA performed in 422 patients from January through December 1999. RESULTS CEMRA was performed to evaluate transient ischemic attack and ischemic stroke in 239 patients, asymptomatic carotid bruit in 88 patients, and other neurological symptoms in 95 patients. Carotid endarterectomies were performed in 97 patients (103 procedures), and conventional angiography was performed in 12 of these patients. CEMRA was used to evaluate for the presence of an arterial dissection in 85 of the 239 patients with transient ischemic attack and ischemic stroke. Of this group, 32 patients had cervical arterial dissection, and pseudoaneurysm was detected in 11 of these patients. Compared with ultrasonography of the cervical vessels, CEMRA provided additional information in 43 of 422 patients and led to changes in the decision as to whether to perform carotid endarterectomy in 5 patients. CONCLUSIONS Use of CEMRA permits noninvasive evaluation of patients suspected of having carotid or vertebral disease and avoids the potential complications of conventional angiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-enhanced magnetic resonance angiography.

With technological advances in magnetic resonance angiography (MRA), spatial resolution of 1-mm perforating vessels can reliably be visualized and accurately located in reference to patients' anatomic landmarks without exposing patients to ionizing radiation or iodinated contrast, resulting in optimal perforator selection, improved flap design, and increased surgical efficiency. As their experi...

متن کامل

Type 1 perimedullary arteriovenous fistula with subarachnoid hemorrhage: utility of contrast-enhanced 3D gradient-echo technique.

PURPOSE In patients with perimedullary arteriovenous fistula (AVF) with subarachnoid hemorrhage (SAH), knowledge of lesion location is necessary to select the appropriate approach for catheter spinal angiography. We evaluated the utility of 3-dimensional (3D) fast imaging with steady-state precession (FISP) sequence for detecting type 1 perimedullary AVF with SAH. MATERIALS AND METHODS We eva...

متن کامل

High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial experience.

The purpose of this study was to prospectively evaluate the diagnostic accuracy of reader detection of 75% or greater stenosis at high-spatial-resolution multistation magnetic resonance (MR) angiography performed with matrix coils and a blood pool contrast agent. Ten healthy volunteers and 10 patients were examined. All participants provided informed consent to participate in this institutional...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Use of Parallel Imaging in Peripheral Contrast-enhanced Magnetic Resonance Angiography: Retrospective Study

Objective: To evaluate the application of a parallel imaging technique — generalised autocalibrating partially parallel acquisition — in peripheral contrast-enhanced magnetic resonance angiography. Patients and Methods: This was a retrospective review of 17 consecutive patients with peripheral vascular disease who underwent lower-extremity 3-dimensional contrast-enhanced magnetic resonance angi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 32 10  شماره 

صفحات  -

تاریخ انتشار 2001