Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.
نویسندگان
چکیده
BACKGROUND Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. METHODS A retrospective review of consecutive cases of porous polyethylene sphere orbital implant exposure. RESULTS Five cases presented between May 2000 and October 2001 (three males, two females; mean age 44.5 years). Three had enucleation (two with primary implants) and two had evisceration (one with primary implant). Exposure occurred in one primary, two secondary, and two replacement implants. Orbital implant diameter was 20 mm in four cases and 16 mm in one case (contracted socket). The mean time from implantation to exposure was 23 months (range 0.7-42.6). Three patients had secondary motility peg placement before exposure. The average time from last procedure (sphere implant or peg insertion) to exposure was 3 months (range 0.7-12.6). Four patients required surgical intervention, of which three needed more than one procedure. Autogenous temporalis fascia grafting successfully closed the defect without re-exposure in three of these four patients. The grafts were left bare in three patients, with a mean time to conjunctivalise of 2.4 months (range 1.6-3.2). CONCLUSIONS Exposed porous polyethylene sphere implants were treated successfully with autogenous temporalis fascia graft in three of four patients. This technique is useful, the graft easy to harvest, and did not lead to prolonged socket inflammation, infection, or extrusion.
منابع مشابه
The Survival of Freely Grafted Orbital Fat on Porous Polyethylene Orbital Implants in the Rabbit
PURPOSE To investigate the long term survival of orbital fat grafted on a Medpor implant as a method of preventing porous polyethylene orbital implant (Medpor) exposure in anophthalmic sockets. METHODS In one orbit in each of 8 rabbits, a small amount of retrobulbar orbital fat was grafted between the anterior surface of the Medpor implant and overlying conjunctiva, during the enucleation and...
متن کاملEffect of basic fibroblast growth factor on fibrovascular ingrowth into porous polyethylene anophthalmic socket implants.
To investigate the effect of basic Fibroblast Growth Factor (bFGF) on fibrovascular ingrowth into porous polyethylene orbital implants (Medpor) and to investigate any differences according to the method of administration. For the treated groups, after evisceration and Medpor implantation, bFGF was administered by soaking Medpor in the bFGF solution, and/or by injecting bFGF into the Medpor 1 we...
متن کاملLong-term surgical outcomes of porous polyethylene orbital implants: a review of 314 cases
PURPOSE This study reports on the long-term surgical outcomes after the insertion of porous Medpor orbital implants into anophthalmic sockets. METHODS A retrospective chart review of 314 eyes from 314 patients who underwent evisceration, enucleation and secondary procedures using Medpor orbital implants was completed focusing on implant-associated complications and their corrective methods as...
متن کاملClinical outcome of 285 Medpor grafts used for craniofacial reconstruction.
Porous polyethylene (Medpor) is an alloplastic material worldwide used for craniofacial reconstruction. To evaluate complications and risk factors associated with this synthetic graft, a retrospective study was performed. A series of 285 Medpor grafts were placed in 187 patients. Age, sex, diagnosis at admission, site, type of surgical insertion, type of fixation, and outcome (no complications,...
متن کاملSix cases of bacterial infection in porous orbital implants.
BACKGROUND We present 6 cases of bacterial infection that developed after porous orbital implant surgery. CASES Five patients with hydroxyapatite implants showed lid swelling, discharge, and suppurative granuloma 14 days to 3 years after surgery. The hydroxyapatite implants were removed 14 days to 41 months postoperatively, and synthetic porous polyethylene orbital implants were inserted. Thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 88 7 شماره
صفحات -
تاریخ انتشار 2004