Transcatheter closure of atrial septal defects with transthoracic echocardiography.
نویسندگان
چکیده
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter measured in different views was selected as the reference diameter. All procedures were performed under conscious sedation with fluoroscopic and transthoracic echocardiographic guidance. RESULTS Between November, 2006 and December, 2009 a secundum-type atrial septal defect was closed with the Amplatzer septal occluder in 40 patients with transthoracic echocardiographic guidance. The mean age and weight were 7.9 years and 26.9 kilograms, respectively. The mean atrial septal defect diameter was 11.4 millimetres, total septal diameter was 38.5 millimetres, and the mean device diameter and the difference between device and atrial septal defect diameter were 12.6 and 1.2 millimetres, respectively. There were no major complications. The mean follow-up time was 14.8 months. CONCLUSION In selected cases, in which the defects are small and the rims are adequate and transthoracic echocardiography provides high image quality, transthoracic echocardiography can be substituted with transoesophageal echocardiography. The ratio of defect size to total septal diameter can be used as a guide for patient selection; those that have a value of 0.33 or greater can be considered eligible for closure with transthoracic echocardiography. However, transthoracic echocardiography should not be used when there are large or multiple defects, or the rims are thin and soft and the image resolution is inadequate.
منابع مشابه
Comparative study of the transcatheter and transthoracic device closure treatments for atrial septal defect
The purpose of this study was to compare patient populations, safety, feasibility, complications, and total costs of the transcatheter and transthoracic device closure treatments for secundum atrial septal defect.From January 2014 to December 2014, we enrolled 155 patients with secundum atrial septal defects in our hospital. The patients were divided into 2 groups: the 70 patients in group A un...
متن کاملTranscatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.
AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...
متن کاملIntegrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملEvaluation of Clinical Course in Children and Adolescents with Atrial Septal Defects
Background Atrial septal defects (ASDs) are the most common third congenital heart defects. This study aimed to evaluate the clinical course of ASDs and the relationship between its complications, location closure and size. Materials and Methods: This cross-sectional study was conducted...
متن کاملFeasibility and Safety of Transthoracic Echocardiography-Guided Transcatheter Closure of Atrial Septal Defects with Deficient Superior-Anterior Rims
Although previous studies showed that transthoracic echocardiography (TTE) can be used to guide transcatheter closure of atrial septal defect (ASD), whether TTE can be used to guide transcatheter closure of secundum ASD with a deficient superior-anterior rim is unknown and this critical issue was addressed in the present study. A total of 280 patients with secundum ASD who underwent transcathet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology in the young
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2011