Diffusion-weighted magnetic resonance imaging of the prostate: improved robustness with stretched exponential modeling.
نویسندگان
چکیده
PURPOSE This study aimed to compare the intraclass correlation coefficients of parameters estimated with stretched exponential and biexponential diffusion models of in vivo diffusion-weighted magnetic resonance imaging (MRI) of the prostate. METHODS After the institutional review board issued a waiver of informed consent for this Health Insurance Portability and Accountability Act-compliant study, 25 patients with biopsy-proven prostate cancer underwent 3T endorectal MRI and diffusion-weighted MRI of the prostate at 10 b values (0, 45, 75, 105, 150, 225, 300, 600, 900, and 1200 s/mm). The full set of b values was collected twice within a single acquisition. Intraclass correlation coefficients were calculated for intra-acquisition variability. From the biexponential model, the quantitative parameters diffusion coefficient (D), perfusion coefficient (D*), and perfusion fraction (f) were estimated. From the stretched exponential model, the quantitative parameters Kohlrausch decay constant (DK) and alpha (α) were estimated. RESULTS For the 25 patient data sets, the average intraclass correlation coefficients for DK and α were 95.8%, and 64.1%, respectively, whereas those for D, D*, and f were 84.4%, 25.3%, and 41.3%, respectively. CONCLUSIONS The stretched exponential diffusion model captures the nonlinear effects of intravoxel incoherent motion in the prostate. The parameters derived from this model are more reliable and reproducible than the parameters derived from the standard, widely used biexponential diffusion/perfusion model.
منابع مشابه
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملEvaluation of different mathematical models for diffusion-weighted imaging of normal prostate and prostate cancer using high b-values: a repeatability study.
PURPOSE To evaluate monoexponential, stretched exponential, kurtosis, and biexponential models for diffusion-weighted imaging (DWI) of normal prostate and prostate cancer (PCa), using b-values up to 2000 s/mm(2) , in terms of fitting quality and repeatability. METHODS Eight healthy volunteers and 16 PCa patients underwent a total of four repeated 3T DWI examinations using 16 and 12 b-values, ...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملCharacterization of continuously distributed cortical water diffusion rates with a stretched-exponential model.
Experience with diffusion-weighted imaging (DWI) shows that signal attenuation is consistent with a multicompartmental theory of water diffusion in the brain. The source of this so-called nonexponential behavior is a topic of debate, because the cerebral cortex contains considerable microscopic heterogeneity and is therefore difficult to model. To account for this heterogeneity and understand i...
متن کاملLimitations and Prospects for Diffusion-Weighted MRI of the Prostate
Diffusion-weighted imaging (DWI) is the most effective component of the modern multi-parametric magnetic resonance imaging (mpMRI) scan for prostate pathology. DWI provides the strongest prediction of cancer volume, and the apparent diffusion coefficient (ADC) correlates moderately with Gleason grade. Notwithstanding the demonstrated cancer assessment value of DWI, the standard measurement and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of computer assisted tomography
دوره 36 6 شماره
صفحات -
تاریخ انتشار 2012