Relationship Between Distance and Change in Surface ECG Morphology During Pacemapping as a Guide to Ablation of Ventricular Arrhythmias: Implications for the Spatial Resolution of Pacemapping.

نویسندگان

  • Anthony Li
  • Joseph Samuel Davis
  • Jeremiah Wierwille
  • Keith Herold
  • Dennis Morgan
  • Elijah Behr
  • Stephen Shorofsky
  • Magdi Saba
چکیده

BACKGROUND Pacemapping is used to localize the exit site of ventricular arrhythmia. Although the relationship between distance and change in QRS morphology is its basis, this relationship has not been systematically quantified. METHODS AND RESULTS Patients (n=68) undergoing ventricular arrhythmia ablation between March 2012 and July 2013 were recruited. Pacemapping was targeted to areas of voltage >0.5 mV. Linear mixed-effects models were constructed of distance against morphology difference measured by the root mean square error sum across all 12 ECG leads (E12). Forty of 68 (58%) patients had structural heart disease, and 21/40 (53%) patients were ischemic. Nine hundred thirty-five pacing points were collected, generating 6219 pacing site pair combinations (3087 [50%] ventricular bodies, 756 [12%] outflow tract, and 162 [3%] epicardial). In multivariable analysis, increase in E12 was predicted by increasing distance (0.07 per mm; 95% confidence interval 0.07-0.08; P<0.001). Compared with the left ventricle, E12 values were lower in the right ventricle (P=0.037) and left ventricular outflow tract (P<0.001) and higher in left ventricle-right ventricle pairs (P=0.021) and left ventricular epicardium (P=0.08). There was no difference in E12 in the right ventricular outflow tract compared with the right-left ventricular outflow tract (P=0.75) pairs. Structural heart disease or inadvertent pacing in scar was not associated with changes in E12; however, the presence of latency and split potentials were associated with higher and lower E12 values, respectively (P<0.001). CONCLUSIONS A robust positive relationship exists between distance and QRS morphological change when restricting pacing points to areas of voltage >0.5 mV. Significant differences in the spatial resolution of pacemapping exist within the heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship Between Distance and Change in Surface ECG Morphology During Pacemapping as a Guide to Ablation of Ventricular Arrhythmias

Pacemapping has been shown to be useful in determining the site of origin or exit site of ventricular arrhythmias (VA) in both idiopathic and scar-related etiologies, particularly, when sustained ventricular tachycardia (VT) is poorly tolerated or ventricular ectopy (VE) occurs at a low frequency. The aim of this study is to quantify the effect of change in distance between pacing sites on the ...

متن کامل

Localization of breakthrough site of canine monomorphic ventricular tachycardia by pacemapping. A vectorial approach.

BACKGROUND The precision and limitations of ventricular pacemapping as a method to localize the site of earliest breakthrough of ventricular tachycardia (VT) were investigated in a canine model of experimental myocardial infarction. METHODS AND RESULTS Forty-one episodes of VT induced in 10 animals were mapped using a standard grid of 64 endocardial and epicardial bipolar electrodes to determ...

متن کامل

The QRS morphology pattern in V5R is a novel and simple parameter for differentiating the origin of idiopathic outflow tract ventricular arrhythmias.

AIMS There are many reports on the ECG characteristics of idiopathic outflow tract ventricular arrhythmias (OT-VAs) to predict their origin. However, differentiating near regions using 12-lead ECGs is still complicated. The synthesized 18-lead ECG derived from the 12-lead ECG can provide virtual waveforms of the right-sided chest leads (V3R, V4R, and V5R) and back leads (V7, V8, and V9). The ai...

متن کامل

Localization of Breakthrough Site of Canine Monomorphic Ventricular Tachycardia

Background. The precision and limitations of ventricular pacemapping as a method to localize the site of earliest breakthrough of ventricular tachycardia (VT) were investigated in a canine model of experimental myocardial infarction. Methods and Results. Forty-one episodes of VT induced in 10 animals were mapped using a standard grid of 64 endocardial and epicardial bipolar electrodes to determ...

متن کامل

Unique preferential conduction within the isolated septal substrate in a patient with ventricular tachycardia complicated with non-ischemic dilated cardiomyopathy.

We describe the case of a 67-year-old woman with non-ischemic dilated cardiomyopathy who underwent successful radiofrequency catheter ablation for ventricular tachycardia (VT) originated from the isolated ventricular septal substrate. Pacemapping exhibited either left, identical to clinical VT, or right bundle branch block like wide QRS morphology. Time interval from the stimulus to QRS onset (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2017