Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.

نویسنده

  • Gerard J Myers
چکیده

The detection and prevention of gaseous microemboli (GMEs) during cardiopulmonary bypass has generated considerable interest within the cardiac surgical community. There have been several landmark papers that have used transcranial Doppler devices during cardiopulmonary bypass to detect gaseous microemboli activity in the patients' middle cerebral artery during perfusionist interventions. To determine if this source of emboli could be prevented, a shunt was developed between the oxygenator's sampling manifold and the oxygenator's venous line. This shunt bypassed the venous line and emptied into the oxygenator's integral cardiotomy. An in vitro experiment was performed using three open system oxygenators (Sorin Synthesis, Sorin PrimeOx2, and Terumo Capiox SX25) to compare post-arterial filter emboli detection using the Hatteland CMD20 Microbubble Detector under tightly controlled conditions. After injection of air through the sampling manifold, the PrimeOx2 and the Synthesis oxygenators had statistically significant fewer GMEs with the shunt used than when the shunt was not used. Using a shunt in the sampling manifold during perfusionist interventions will dramatically reduce or eliminate gaseous microemboli transmission to the patient during bypass with both the PrimeOx2 and Synthesis oxygenators. However, results indicate that further study of GME handling with all oxygenator's integral cardiotomies is warranted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.

Potential sources of gaseous microemboli during cardiopulmonary bypass are varied. However, it is known that membrane oxygenators generate fewer gaseous microemboli than bubble oxygenators and that bubblers cannot utilize arterial heat exchange without generating significant gaseous microemboli during rewarming. A membrane oxygenator utilizing simultaneous gas and heat exchange raises the con...

متن کامل

In-Vitro Evaluation of Two Types of Neonatal Oxygenators in Handling Gaseous Microemboli and Maintaining Optimal Hemodynamic Stability During Cardiopulmonary Bypass

Objective Usually only FDA-approved oxygenators are subject of studies by the international scientific community. The objective of this study is to evaluate two types of neonatal membrane oxygenators in terms of transmembrane pressure gradient, hemodynamic energy transmission and gaseous microemboli capture in simulated cardiopulmonary bypass systems. Methods We investigated the Braile Infant...

متن کامل

Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.

When conventional gravity siphon venous drainage cannot achieve satisfactory venous drainage during minimally invasive cardiac and neonatal surgeries, assisted venous drainage techniques are needed to ensure adequate flow. One assisted venous drainage technique, vacuum-assisted venous drainage (VAVD), the aid of a vacuum in the venous reservoir, is now widely used to augment venous drainage dur...

متن کامل

Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.

BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...

متن کامل

Blood temperature management and gaseous microemboli creation: an in-vitro analysis.

Gaseous microemboli have been associated with post operative neurological deficits in patients undergoing cardiopulmonary bypass. Creating an optimal perfusion system that minimizes microemboli production and has enhanced abilities to sequester entrained air during the bypass procedure has been an important focus. This study examines the air-handling capabilities of a cardiopulmonary bypass cir...