Hemagglutination treponemal test for syphilis.

نویسندگان

  • G Friedly
  • M V Zartarian
  • J C Wood
  • C M Floyd
  • E M Peterson
  • L M de la Maza
چکیده

Sera from 290 hospital patients were tested to compare the sensitivity, specificity, and reproducibility of the hemagglutination treponemal test for syphilis (HATTS) with the fluorescent treponemal antibody absorption test (FTA-ABS). Complete agreement was obtained between the methods when 142 syphilitic sera from patients with various stages of syphilis were tested. By using clinical histories, the specificity with 148 nonsyphilitic sera was determined to be 100% for the HATTS and 96.6% (143 of 148) for the FTA-ABS. Satisfactory reproducibility was obtained with both methods. Compared with the FTA-ABS, the HATTS was more specific, easier, and more economical to perform. We therefore recommend the HATTS as a suitable alternative to the FTA-ABS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.

Sera from 628 nonsyphilitic individuals were tested with the Rapid Plasma Reagin-Card, Fluorescent Treponemal Antibody-Absorbed, and Hemagglutination Treponemal Test for Syphilis tests to ascertain the comparative specificity of these tests. Many sera were also tested with the quantitative Venereal Disease Research Laboratory test. Sera included in the study were from both normal individuals an...

متن کامل

Heated versus unheated sera in the hemagglutination treponemal test for syphilis.

Sera (920) were tested to evaluate the use of heated versus unheated sera in the hemagglutination treponemal test for syphilis. The heated and unheated samples were tested on the same day with the hemagglutination treponemal test for syphilis kit according to the manufacturer's protocol. Agreement of results between the heated and unheated sera was 99.2%. The reading pattern of agglutination wa...

متن کامل

Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis.

The BioElisa Syphilis, a new competitive enzyme immunoassay (EIA) for Treponema pallidum whole antigen that uses specific human immunoglobulin G (IgG) antibodies as the competitor, was evaluated for potential use in screening for syphilis at various stages. The results obtained by this competitive EIA were compared with those obtained by the fluorescent treponemal antibody absorption (FTA-abs) ...

متن کامل

Diagnostic dilemma of the single screening test used in the diagnosis of syphilis in Nepal.

Syphilis screening by the nontreponemal rapid plasma reagin (RPR) test is not usually followed up by specific treponemal tests in most of the resource poor healthcare settings of Nepal. We analyzed serum specimens of 504 suspected syphilis cases at the immunology department of the national reference laboratory in Nepal during 2007-2009 using RPR test and Treponema pallidum hemagglutination assa...

متن کامل

HIV-positive man with ulceronecrotic skin lesions.

Diagnosis: malignant syphilis and coinfection with human immunodeficiency virus (HIV). A skin biopsy was performed, and the diagnosis of syphilis was suggested by the histopathological findings (figure 1). Titers of Treponema pallidum were 11:64 on hemagglutination assay, and a fluorescent treponemal antibody absorption test had positive results. After treatment with intravenous penicillin G (1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 1983