Assessing the accuracy of contact angle measurements for sessile drops on liquid-repellent surfaces.
نویسندگان
چکیده
Gravity-induced sagging can amplify variations in goniometric measurements of the contact angles of sessile drops on super-liquid-repellent surfaces. The very large value of the effective contact angle leads to increased optical noise in the drop profile near the solid-liquid free surface and the progressive failure of simple geometric approximations. We demonstrate a systematic approach to determining the effective contact angle of drops on super-repellent surfaces. We use a perturbation solution of the Bashforth-Adams equation to estimate the contact angles of sessile drops of water, ethylene glycol, and diiodomethane on an omniphobic surface using direct measurements of the maximum drop width and height. The results and analysis can be represented in terms of a dimensionless Bond number that depends on the maximum drop width and the capillary length of the liquid to quantify the extent of gravity-induced sagging. Finally, we illustrate the inherent sensitivity of goniometric contact angle measurement techniques to drop dimensions as the apparent contact angle approaches 180°.
منابع مشابه
Sessile and Pendant Micro-Liter Drops Evaporate at Different Rates: An Experimental Approach
Evaporation of micro-liter drops from solid surfaces at room condition is mainly governed by diffusion. Therefore, there should be no difference between evaporation rate of sessile and pendant drops. However, some studies indicate a difference and explain the difference using buoyancy. The objective here is to reconcile the inconsistency in the literature. For that, first, by comparing two iden...
متن کاملWetting and absorption of water drops on Nafion films.
Water drops on Nafion films caused the surface to switch from being hydrophobic to being hydrophilic. Contact angle hysteresis of >70 degrees between advancing and receding values were obtained by the Wilhelmy plate technique. Sessile drop measurements were consistent with the advancing contact angle; the sessile drop contact angle was 108 degrees . Water drop adhesion, as measured by the detac...
متن کاملHow Water Advances on Superhydrophobic Surfaces.
Superliquid repellency can be achieved by nano- and microstructuring surfaces in such a way that protrusions entrap air underneath the liquid. It is still not known how the three-phase contact line advances on such structured surfaces. In contrast to a smooth surface, where the contact line can advance continuously, on a superliquid-repellent surface, the contact line has to overcome an air gap...
متن کاملCorrection to "Contact Angle of Sessile Drops in Lennard-Jones Systems".
Molecular dynamics simulations are used for studying the contact angle of nanoscale sessile drops on a planar solid wall in a system interacting via the truncated and shifted Lennard-Jones potential. The entire range between total wetting and dewetting is investigated by varying the solid-fluid dispersive interaction energy. The temperature is varied between the triple point and the critical te...
متن کاملPhase field modeling of hysteresis in sessile drops.
We propose a novel approach to describe wetting of plane solid surfaces by liquid drops. A two-dimensional nonconserved phase field variable is employed to distinguish between wetted and nonwetted regions on the surface. The imbalance in the Young's force provides for the exchange of relative stability of the two phases. The three-phase contact line tension arises from the gradient energy and c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Langmuir : the ACS journal of surfaces and colloids
دوره 27 22 شماره
صفحات -
تاریخ انتشار 2011