Sequential injection technique for automated titration: spectrophotometric assay of vitamin C in pharmaceutical products using cerium(IV) in sulfuric acid.
نویسندگان
چکیده
For the first time sequential injection analysis (SIA) technique has been employed for titrimetry. A new SI titrimetric spectrophotometric method for the assay of vitamin C in drug formulations was explored. The method is based on the oxidation reaction of vitamin C with cerium(IV) in sulfuric acid media using a spectrophotometer as a detector with the wavelength monitored at 410 nm. A 2(3) factorial design chemometric approach was employed to study the interaction effect of the chemical and system variables, mainly cerium(IV), sulfuric acid concentrations and the flow rate. The results of the chemometric optimization revealed that the optimum operating conditions for the SI titrimetric analysis of vitamin C were 7.0 x 10(-3) M cerium(IV), 0.455 M sulfuric acid and 28.9 microL s-1 flow rate. A linear calibration plot for the determination of vitamin C was obtained in the concentration range between 30 to 200 ppm. The method was applied to the determination of vitamin C in pharmaceutical preparations and no excipient was found to pose any interference, thus rendering the method suitable for the determination of the drug in pharmaceutical preparations. The SIA method is found to be accurate when the results were statistically compared with the results obtained by the BP standard method. The SIA method is superior when compared to the conventional titration method, the BP standard method and previous methods with respect to precision and automation in solution handling.
منابع مشابه
Differential electrolytic potentiometry, a detector in flow injection analysis for oxidation-reduction reactions.
For the first time, differential electropotentiometry (DEP) is coupled with the flow injection analysis (FIA) technique for detection of oxidation-reduction reactions, and is utilized for quantitative determination of vitamin C in pharmaceutical preparations using 1.0x10(-3)-M cerium(IV) in 0.50-M sulfuric acid as carrier. Two similar platinum electrodes were employed and polarized by a constan...
متن کاملVolumetric and spectrophotometric determination of oxcarbazepine in tablets.
Two cerimetric procedures are described for the assay of oxcarbazepine (OXC) in bulk drug and in tablets. Titrimetry (method A) is based on the reaction of OXC by a measured excess cerium(IV) sulphate in sulphuric acid medium and the determination of the unreacted oxidant by titration with iron(II) solution using ferroin as indicator. Spectrophotometry (method B) is based on oxidation of OXC by...
متن کاملEvaluation of the stability of iron(II) solutions by precise coulometric titration with electrogenerated cerium(IV).
An iron(II) solution is often used as a reducing agent in titrimetry and standardized with cerium(IV) or potassium dichromate. Such an iron(II) standard solution is needed for not only titrimetric analyses, but also instrumental ones. Iron(II) is unstable even in a highly acidic solution, mainly due to air-oxidation; therefore, its standardization is required before use. In the present study...
متن کاملTitrimetric and Spectrophotometric Methods for the Assay of Ketotifen Using Cerium(IV) and Two Reagents
One titrimetric and two spectrophotometric methods are described for the determination of ketotifen fumarate (KTF) in bulk drug and in tablets using cerium(IV) as the oxidimetric agent. In titrimetry (method A), the drug was treated with a measured excess of cerium(IV) in H2SO4 medium and after a standing time of 10 min, the surplus oxidant was determined by back titration with iron(II). The sp...
متن کاملElectron spin resonance for quantitative assay of chlorpromazine in drug formulations by oxidation with cerium(IV) in sulfuric acid media.
For the first time electron spin resonance (ESR) spectroscopic technique has been used for a highly selective determination of chlorpromazine. The method is based on the oxidation reaction of chlorpromazine with cerium(IV) in sulfuric acid media. In this method 3.8x10(-3) mol dm(-3) cerium(IV) was used in 0.035 mol dm(-3) sulfuric acid with the ESR spectra recorded at room temperature. A calibr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 124 6 شماره
صفحات -
تاریخ انتشار 1999