Generator Columns and High Pressure Liquid Chromatography for Determining Aqueous Solubilities and Octanol-Water Partition Coefficients of Hydrophobic Substances

نویسندگان

  • Howard DeVoe
  • Michele M. Miller
چکیده

Generator columns packed with a solid support and loaded with a liquid organic phase make it possible to rapidly and conveniently equilibrate water with the organic phase. By coupling the generator column to an extractor column for high pressure liquid chromatographic analysis of the aqueous solution, errors from surface adsorption and loss to the atmosphere are avoided. Using this method, the mean values and confidence limits at a 95 percent confidence level of the aqueous solubility, S, and the octanol-water partition coefficient, P, of n-propylbenzene at 25°C were found to be S = (4.32 ± 0.02) X 1O-M and log P = 3.720 ± 0.003.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of n-octanol/water partition coefficients of weak ionizable solutes by RP-HPLC with neutral model compounds.

The utilization of neutral compounds as model compounds is put forward for determination of the n-octanol/water partition coefficient (K(ow)) of highly hydrophobic, weak acidic compounds by reversed-phase high performance liquid chromatography (RP-HPLC). It is based on a linear relationship between the logarithm of apparent n-octanol/water partition coefficient (log K(ow)″), expressing hydropho...

متن کامل

Comparison of Aqueous and 1-Octanol Solubility as well as Liquid–Liquid Distribution of Acyclovir Derivatives and Their Complexes with Hydroxypropyl-β-Cyclodextrin

The aim of the presented work is the comparison of aqueous and 1-octanol solubilities of different acyclovir derivatives and their hydroxypropyl-β-cyclodextrin inclusion complexes. The solubility measurements were carried out at different temperatures over the range 25-45 °C using water, 1-octanol, water saturated with 1-octanol, 1-octanol saturated with water, buffered aqueous solutions (pH = ...

متن کامل

Rapid determination of octanol-water partition coefficient using vortex-assisted liquid-liquid microextraction.

Vortex-assisted liquid-liquid microextraction (VALLME) coupled with high-performance liquid chromatography (HPLC) is proposed here for the rapid determination of octanol-water partitioning coefficients (Kow). VALLME uses vortex agitation, a mild emulsification procedure, to disperse microvolumes of octanol in the aqueous phase thus increasing the interfacial contact area and ensuring faster par...

متن کامل

Countercurrent chromatography: a worthy technique for the direct measurement of liquid-liquid partition coefficients

Countercurrent chromatography (CCC) is a liquid chromatography technique in which the stationary phase is also a liquid. The solute separation is based on partitioning between the two immiscible liquid phases: the mobile phase and the support-free liquid stationary phase. Octanol-water partition coefficients (Po/w) of 17 βblockers and 17 sulphonamides were determined by CCC. Some of the Po/w co...

متن کامل

Aqueous solubility, effects of salts on aqueous solubility, and partitioning behavior of hexafluorobenzene: experimental results and COSMO-RS predictions.

The aqueous solubility of hexafluorobenzene has been determined, at 298.15K, using a shake-flask method with a spectrophotometric quantification technique. Furthermore, the solubility of hexafluorobenzene in saline aqueous solutions, at distinct salt concentrations, has been measured. Both salting-in and salting-out effects were observed and found to be dependent on the nature of the cationic/a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010