Uncertainty Evaluation of a 3d Vision System: Comparison of Monte Carlo Simulation with a Classical Experimental Calibration

نویسندگان

  • J. Sola
  • F. J. Brosed
  • J. J. Aguilar
  • María de Luna
چکیده

The Guide to the Expression of Uncertainty in Measurement has some limitations, especially for systems with complex mathematical models. In this article, two alternative methods to obtain the measurement uncertainty (Monte-Carlo simulation and calibration based on experimental measurement) are compared. These methods are widely used to calculate the measurement uncertainty of measurement systems. The advantages and disadvantages of these two methods are going to be studied estimating the uncertainty of the flatness measurement using a system based on laser triangulation. The measurement system captures images of the laser plane projected in the surface to be digitalized. The laser points in each image are identified and extracted and transformed into 3D coordinates to calculate the flatness of the surface. The influence of different factors will be characterized and the results of the estimation of the uncertainty with both Monte Carlo simulation and the calibration based on experimental measurement will be compared as well as the characteristics and requirements of each procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

متن کامل

Evaluating How the Islamic Republic of Iran Achieved its Vision Economic Goals by Designing and Computing a Composite Index and Using Monte Carlo Simulation Approach for Uncertainty Analysis

The Islamic Republic of Iran Vision aimed to direct development plans and yearly budgets. As one of the most important part, it includes 13 economic goals for directing economic route of the country for a twenty years period. After 15 years, evaluating how the country achieved to these goals is very important and unfortunately neglected. In this article, considering the different nature of goal...

متن کامل

Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

متن کامل

Sensitivity and uncertainty analysis of sediment rating equation coefficients using the Monte-Carlo simulation (Case study: Zoshk-Abardeh watershed, Shandiz)

The sediment load estimation is essential for watershed management and soil conservation strategies. The sediment rating curve is the most common approach for estimating the sediment load when the observed sediment records are not available. With regard to the measurement errors and the limitation of available data, the sediment rating curve has a degree of uncertainty which should be accounted...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013