Regional gap junction inhibition increases defibrillation thresholds.
نویسندگان
چکیده
It is clear that ischemia inhibits successful defibrillation by altering regional electro-physiology. However, the exact mechanisms are unclear. This study investigated whether regional gap junction inhibition increases biphasic shock defibrillation thresholds (DFT). Sixteen swine were instrumented with a mid-left anterior descending (LAD) perfusion catheter for regional infusion of 0.5 mM/h heptanol (n = 8) or saline (n = 8). DFT values and effective refractory periods (ERP) at five myocardial sites were determined. Regional conduction velocity (CV) was determined in an LAD drug-perfused and nondrug-perfused region in an additional seven swine. Regional heptanol infusion increased 50% DFT values by 33% (P = 0.01) and slowed CV by 42-59% (P < 0.01) but did not affect ERP. Regional heptanol also increased CV dispersion by approximately 270% (P < 0.05) but did not change ERP dispersion. Regional placebo did not alter any of these parameters. Furthermore, regional heptanol infusion induced spontaneous ventricular fibrillation in eight of eight animals. Increasing spatial conduction velocity dispersion by impairing regional gap junction conductance increased DFT values. Dispersion in conduction velocity slowing during regional ischemia may be an important determinant of defibrillation efficacy.
منابع مشابه
Effects of rotigaptide, a gap junction modifier, on defibrillation energy and resuscitation from cardiac arrest in rabbits.
The gap junction modifier Rotigaptide (ZP123), which promotes cellular coupling, was hypothesized to decrease defibrillation thresholds during prolonged ventricular fibrillation (VF). Thirty-two New Zealand white rabbits were randomized to receive saline (control, n = 16) or Rotigaptide (n = 16). Following 4 min of untreated VF, biphasic defibrillation shocks were applied through chest wall pat...
متن کاملGap junction blockers decrease defibrillation thresholds without changes in ventricular refractoriness in isolated rabbit hearts.
BACKGROUND The maintenance and termination of reentry arrhythmias are determined by tissue properties such as refractoriness and conduction velocity. Although the effects of Na(+) and K(+) channel block on electrophysiological properties and defibrillation threshold (DFT) have been studied, little is known about the effect of gap junction blockers on defibrillation and tissue electrophysiologic...
متن کاملEffects of inhibition of prostaglandin synthesis on uterine oxytocin receptor concentration and myometrial gap junction density in parturient rats.
The development of oxytocin (OT) sensitivity in the parturient uterus is associated with increases in myometrial OT receptor concentration, gap junction formation, and prostaglandin (PG) production. To investigate whether PGs mediate these responses, we measured OT responsiveness, OT receptor concentrations, and gap junction formations in uteri of Day 19, 20, 21, 22, 23 pregnant and Day 2 postp...
متن کاملAzygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement
Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.
متن کاملIntracerebroventricular Injection of Lipopolysaccharide Increases Gene Expression of Connexin32 Gap Junction in Rat Hippocampus
Introduction: Gap junctions are intercellular membrane channels that provide direct cytoplasmic continuity between adjacent cells. This communication can be affected by changes in expression of gap junctional subunits called Connexins (Cx). Changes in the expression and function of connexins are associated with number of brain neurodegenerative diseases. Neuroinflammation is a hallmark of vario...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 285 1 شماره
صفحات -
تاریخ انتشار 2003