Evaluation of the Binax NOW, BD Directigen, and BD Directigen EZ assays for detection of respiratory syncytial virus.

نویسندگان

  • Marilyn J Ohm-Smith
  • Patricia S Nassos
  • Barbara L Haller
چکیده

The Binax NOW assay (Binax, Inc., Portland, Maine) and the BD Directigen EZ assay (Becton Dickinson and Company, Sparks, Md.), two new rapid immunoassays for detection of respiratory syncytial virus (RSV), as well as the BD Directigen RSV assay (DRSV) (Becton Dickinson and Company) and direct immunofluorescence staining (DFA) were compared with culture for detection of RSV in fresh specimens from both children and adults during the 2002-2003 respiratory virus season. The majority (95%) of specimens were nasal or nasopharyngeal washes or aspirates. A total of 47 (26%) were culture positive for RSV. The overall sensitivities of DFA (n = 149), NOW (n = 118), EZ (n = 88), and DRSV (n = 180) compared with culture (n = 180) were 93, 89, 59, and 77%, respectively. The specificities of DFA, NOW, EZ, and DRSV were 97, 100, 98, and 96%, respectively. However, when results were separated into those from children and those from adults, DFA was the only rapid test adequate for detection of RSV (sensitivity of 100% compared to 0, 0, and 25% for NOW, EZ, and DRSV, respectively) in adults. For children the sensitivities of DFA, NOW, EZ, and DRSV were 93, 94, 72, and 81%. The NOW assay was the most sensitive and specific and the easiest to perform of the kit tests for detecting RSV in children. None of these three rapid kit tests was sensitive for detecting RSV in specimens from adults. DFA remains the rapid method of choice for detecting RSV in the adult population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of influenza rapid point‐of‐care tests in the detection of swine lineage A(H1N1) influenza viruses

BACKGROUND In April 2009, an A(H1N1) influenza virus of swine lineage was detected in humans in the USA, and in just over a month has infected over 10,000 people in more than 40 countries. OBJECTIVES To determine the performance of the Binax Now, BD Directigen EZ, and the Quidel QuickVue influenza rapid point-of-care (POC) tests for the detection of the recently emerged swine lineage A(H1N1) ...

متن کامل

Comparison of Cepheid's analyte-specific reagents with BD directigen for detection of respiratory syncytial virus.

For detection of respiratory syncytial virus (RSV), the BD Directigen RSV rapid antigen assay was compared to Cepheid's real-time reverse transcriptase PCR RSV analyte-specific reagents. The Directigen RSV assay resulted in a 23% false-negative rate, using PCR and chart review as the gold standard, indicating that rapid RSV PCR results would be advantageous.

متن کامل

Evaluation of the Becton Dickinson Rapid Influenza Diagnostic Tests in Outpatients in Germany during Seven Influenza Seasons

BACKGROUND An extensive retrospective study spanning several seasons was undertaken to evaluate the diagnostic performance of the BD rapid influenza diagnostic test (RIDT) in comparison with the RT-PCR assay. METHODS A total of 2,179 respiratory samples were tested in parallel by in-house RT-PCR and the RIDT. During the 2003-2004, 2006-2007, 2007-2008, and 2008-2009 (n=1671) seasons, the BD D...

متن کامل

Comparison of BD DirectigenTM EZ RSV and Remel X/pectTM RSV Rapid Chromatographic Immunoassays to Direct Immunofluorescence for Detection of Respiratory Syncytial Virus in Pediatric Patients

Two rapid lateral flow chromatographic immunoassays (RLFCIs), the BD DirectigenTM EZ RSV (BD Diagnostics, Sparks, MD) and X/pectTM RSV (Remel Inc., Lenexa, KS) tests, were compared to a direct immunofluorescence (DFA) assay for detection of respiratory syncytial virus (RSV) in nasopharyngeal aspirates from pediatric patients. Our study of RLFCIs was focused on testing frozen patient specimens. ...

متن کامل

Comparison of LightCycler PCR, rapid antigen immunoassay, and culture for detection of group A streptococci from throat swabs.

We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 7  شماره 

صفحات  -

تاریخ انتشار 2004