Exploratory studies of extended storage of apheresis platelets in a platelet additive solution (PAS).

نویسندگان

  • Sherrill J Slichter
  • Jill Corson
  • Mary Kay Jones
  • Todd Christoffel
  • Esther Pellham
  • S Lawrence Bailey
  • Doug Bolgiano
چکیده

To evaluate the poststorage viability of apheresis platelets stored for up to 18 days in 80% platelet additive solution (PAS)/20% plasma, 117 healthy subjects donated platelets using the Haemonetics MCS+, COBE Spectra (Spectra), or Trima Accel (Trima) systems. Control platelets from the same subjects were compared with their stored test PAS platelets by radiolabeling their stored and control platelets with either (51)chromium or (111)indium. Trima platelets met Food and Drug Administration poststorage platelet viability criteria for only 7 days vs almost 13 days for Haemonetics platelets; ie, platelet recoveries after these storage times averaged 44 ± 3% vs 49 ± 3% and survivals were 5.4 ± 0.3 vs 4.6 ± 0.3 days, respectively. The differences in storage duration are likely related to both the collection system and the storage bag. The Spectra and Trima platelets were hyperconcentrated during collection, and PAS was added, whereas the Haemonetics platelets were elutriated with PAS, which may have resulted in less collection injury. When Spectra and Trima platelets were stored in Haemonetics' bags, poststorage viability was significantly improved. Platelet viability is better maintained in vitro than in vivo, allowing substantial increases in platelet storage times. However, implementation will require resolution of potential bacterial overgrowth during storage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regular Article TRANSFUSION MEDICINE Exploratory studies of extended storage of apheresis platelets in a platelet additive solution (PAS)

• Extended apheresis platelet storage is dependent on the collection method, storage in a storage solution, and storage bag composition. • The lifespan of the platelet is not intrinsic to the cell, and platelet viability is better maintained in vitro than in vivo. To evaluate the poststorage viability of apheresis platelets stored for up to 18 days in 80% platelet additive solution (PAS)/20% pl...

متن کامل

Comparative in vitro evaluation of apheresis platelets stored with 100% plasma versus bicarbonated Ringer's solution with less than 5% plasma.

BACKGROUND The major strategy for reducing the frequency of adverse reactions to platelet (PLT) transfusions is PLT washing with PLT additive solutions (PASs). In Japan, a mixture of medical infusion solutions such as acetate Ringer's solution, sodium bicarbonate, magnesium sulfate, and ACD-A is currently used as a PAS because none of the common types of PASs are officially permitted for clinic...

متن کامل

A multicenter randomized study of the efficacy of transfusions with platelets stored in platelet additive solution II versus plasma.

Randomized studies testing the clinical efficacy of platelet additive solutions (PASs) for storage of platelets are scarce and often biased by patient selection. We conducted a multicenter, randomized study to investigate clinical efficacy of platelets stored in PAS II versus plasma, also including patients with clinical complications associated with increased platelet consumption. A total of 1...

متن کامل

Treatment of buffy coat platelets in platelet additive solution with the mirasol(®) pathogen reduction technology system.

BACKGROUND The Mirasol pathogen reduction technology (PRT) system uses riboflavin and ultraviolet light and is currently approved and used in Europe for the treatment of platelets and plasma. Mirasol treatment is intended to reduce the infectious pathogen load and to inactivate leukocytes in blood products. Our objective was to evaluate buffy coat platelet concentrates (BCPCs) prepared with pla...

متن کامل

Evaluation of Biochemical Parameters of Platelet Concentrates Stored in Plasma or in A Platelet Additive Solution (Composol)

Abstract Objective Removing plasma from the platelet concentrate (PC) medium could be an effective way to increase the safety of this product. The goal of this study was to compare PC stored in plasma or in an additive solution (Composol) with in vitro testing. Materials and Methods Fifty-four single donor PCs were prepared from Iranian Blood Transfusion Organization (IBTO). Each PC unit wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Blood

دوره 123 2  شماره 

صفحات  -

تاریخ انتشار 2014