Background Suppression Does Not Reduce Physiological Noise in Myocardial ASL Perfusion Imaging

نویسندگان

  • Z. Zun
  • E. C. Wong
  • K. S. Nayak
چکیده

Introduction Myocardial blood flow (MBF) measurement in humans using arterial spin labeling (ASL) shows promise but has produced highly variable results [1-4]. One critical source of measurement errors is the physiological noise caused by static tissue mis-registration due to metabolic fluctuation, respiratory and cardiac motion, and other unknown variations over time [5]. Background suppression (BGS) [6-7] has been widely used in brain ASL as a means to reduce such physiological noise. We performed myocardial ASL scans with and without BGS, and investigated if the use of BGS reduces physiological noise. If the high physiological noise stems from misregistration of myocardial tissue, it has to be reduced by the use of BGS. We determined that the change in physiological noise using BGS is not statistically significant, and that the source of physiological noise is unlikely to relate to mis-registration of myocardium. Methods Figure 1 illustrates the cardiac gated FAIR [8] sequences with and without BGS. Inversion and imaging are both centered at mid-diastole. One pair of control and tagged images was acquired 6 s apart during a single breath-hold with an identical inversion delay, and six breath-holds (10-12 s each) were used for signal averaging. Image acquisition was performed using a snapshot SSFP, and the inversions were achieved using adiabatic (hyperbolic secant) pulses. For BGS, extra saturation on the slab containing imaging slice and nonselective inversion were added with real-time adjusting timing to suppress myocardial signal on the imaging time in the presence of variable heart rate. Experiments were performed on a GE Signa 3.0 T EXCITE with an 8-channel cardiac array coil. Regions of septal myocardium on mid-short axis were manually segmented for each breath-hold. On the region of interest, we measured myocardial tissue signal on control and tagged images, estimated MBF measurements using Buxton’s general kinetic model [9], and calculated the probability of MBF measurement error being < 0.1 ml/ml/min based on the standard deviation of measurements from six breath-holds with a Gaussian model of physiological noise [5]. Results Table 1 summarizes the results from all ten scans. Using BGS, the myocardial tissue signal was reduced by 82%, MBF estimates decreased by 44%, and measurement confidence decreased slightly. Using t-tests, the decrease in measured MBF was found to be statistically significant (p=0.0004) while the change in measurement confidence was found to be statistically insignificant (p=0.47). Discussion Cardiac-gated FAIR already has relatively low myocardial signal, and BGS pulses were able to reduce this further by 82%. Results from ten scans show that BGS produced no significant change in physiological noise, which suggests that static tissue mis-registration in the subtraction is not a significant source of physiological noise in human myocardial ASL. Measured MBF was lower with BGS, and may be due to the long saturation duration (20ms) or imperfect inversion. References [1] Poncelet BP et al, MRM 41:510, 1999. [2] Wacker CM et al, JMRI 18:555, 2003. [3] An J et al, 13 ISMRM p253, 2005. [4] Zhang H et al, MRM 53:1135, 2005. [5] Zun Z et al, MRM submitted, 2008. [6] Ye FQ et al, MRM 44:92, 2000. [7] Duyn JH et al, MRM 46:88, 2001. [8] Kim SG, MRM 34:293, 1995. [9] Buxton RB et al, MRM 40:383, 1998. Scan FAIR FAIR with BGS Myo. signal ratio (%) Myo. signal (%) MBF Conf. (%) Myo. signal (%) MBF Conf. (%)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial ASL-CMR perfusion imaging with improved sensitivity using GRAPPA

Background Myocardial arterial spin labeling (ASL) is a non-contrast CMR technique for measuring myocardial blood flow (MBF), but has relatively low signal-to-physiological noise (PN). Therefore perfusion measurements are made over several averaged pixels within left ventricular (LV) segments and not individual pixels. Shorter image acquisition times using SENSE parallel imaging has been shown ...

متن کامل

Double-gated myocardial ASL perfusion imaging is robust to heart rate variation.

PURPOSE Cardiac motion is a dominant source of physiological noise (PN) in myocardial arterial spin labeled (ASL) perfusion imaging. This study investigates the sensitivity to heart rate variation (HRV) of double-gated myocardial ASL compared with the more widely used single-gated method. METHODS Double-gating and single-gating were performed on 10 healthy volunteers (n = 10, 3F/7M; age, 23-3...

متن کامل

Mapping of Myocardial ASL Perfusion and Perfusion Reserve Data

INTRODUCTION: Arterial spin labeling (ASL) is an emerging tool for the assessment of myocardial perfusion and perfusion reserve in humans. This technique requires registration of multiple images and suffers from low signal-to-noise ratio (SNR) [1-4]. In this work, we present a novel approach for mapping perfusion and perfusion reserve based on ASL data. Unregistered spatial data is transformed ...

متن کامل

Myocardial arterial spin labeling perfusion imaging with improved sensitivity

BACKGROUND Myocardial arterial spin labeling (ASL) is a noninvasive MRI based technique that is capable of measuring myocardial blood flow (MBF) in humans. It suffers from poor sensitivity to MBF due to high physiological noise (PN). This study aims to determine if the sensitivity of myocardial ASL to MBF can be improved by reducing image acquisition time, via parallel imaging. METHODS Myocar...

متن کامل

Improving CBF MRI using a Background Suppression in cASL with a Separate Labeling Coil

INTRODUCTION In arterial spin labeling (ASL) MRI of cerebral blood flow (CBF), pair-wise subtraction of adjacent non-labeled and labeled images often could not achieve complete cancellation of the background static tissue signal because of temporally fluctuating physiological noise. While background suppression (BS) by inversion nulling has been shown to improve CBF temporal stability (1–5), im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008