Modeling the relation between cardiac pump function and myofiber mechanics.
نویسندگان
چکیده
Complexity of the geometry and structure of the heart hampers easy modeling of cardiac mechanics. The modeling can however be simplified considerably when using the hypothesis that in the normal heart myofiber structure and geometry adapt, until load is evenly distributed. A simple and realistic relationship is found between the hemodynamic variables cavity pressure and volume, and myofiber load parameters stress and strain. The most important geometric parameter in the latter relation is the ratio of cavity volume to wall volume, while actual geometry appears practically irrelevant. Applying the found relationship, a realistic maximum is set to left ventricular pressure after chronic pressure load. Pressures exceeding this level are likely to cause decompensation and heart failure. Furthermore, model is presented to simulate left and right ventricular pump function with left-right interaction.
منابع مشابه
Determinants of biventricular cardiac function: a mathematical model study on geometry and myofiber orientation
In patient-specific mathematical models of cardiac electromechanics, usually a patient-specific geometry and a generic myofiber orientation field are used as input, upon which myocardial tissue properties are tuned to clinical data. It remains unclear to what extent deviations in myofiber orientation and geometry between model and patient influence model predictions on cardiac function. Therefo...
متن کاملIntra- and interventricular asynchrony of electromechanics in the ventricularly paced heart
The degree of restoration of pump function by ventricular pacing depends on the pacing site and timing of pacing. Numerical models of cardiac electromechanics could be used to investigate the relation between the ventricular pacing site and timing on the one side, and pump function on the other. In patient-specific models, these numerical models could be used to optimize location and timing for...
متن کاملWhy SIT Works: Normal Function Despite Typical Myofiber Pattern in Situs Inversus Totalis (SIT) Hearts Derived by Shear-induced Myofiber Reorientation
The left ventricle (LV) of mammals with Situs Solitus (SS, normal organ arrangement) displays hardly any interindividual variation in myofiber pattern and experimentally determined torsion. SS LV myofiber pattern has been suggested to result from adaptive myofiber reorientation, in turn leading to efficient pump and myofiber function. Limited data from the Situs Inversus Totalis (SIT, a complet...
متن کاملStructure and torsion in the normal and situs inversus totalis cardiac left ventricle. II. Modeling cardiac adaptation to mechanical load.
Mathematical models provide a suitable platform to test hypotheses on the relation between local mechanical stimuli and responses to cardiac structure and geometry. In the present model study, we tested hypothesized mechanical stimuli and responses in cardiac adaptation to mechanical load on their ability to estimate a realistic myocardial structure of the normal and situs inversus totalis (SIT...
متن کاملEffects of activation pattern and active stress development on myocardial shear in a model with adaptive myofiber reorientation.
It has been hypothesized that myofiber orientation adapts to achieve a preferred mechanical loading state in the myocardial tissue. Earlier studies tested this hypothesis in a combined model of left ventricular (LV) mechanics and remodeling of myofiber orientation in response to fiber cross-fiber shear, assuming synchronous timing of activation and uniaxial active stress development. Difference...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 36 5 شماره
صفحات -
تاریخ انتشار 2003