Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.

نویسندگان

  • John B Ludlow
  • Marija Ivanovic
چکیده

OBJECTIVES This study compares 2 measures of effective dose, E(1990) and E(2007), for 8 dentoalveolar and maxillofacial cone-beam computerized tomography (CBCT) units and a 64-slice multidetector CT (MDCT) unit. STUDY DESIGN Average tissue-absorbed dose, equivalent dose, and effective dose were calculated using thermoluminescent dosimeter chips in a radiation analog dosimetry phantom. Effective doses were derived using 1990 and the superseding 2007 International Commission on Radiological Protection (ICRP) recommendations. RESULTS Large-field of view (FOV) CBCT E(2007) ranged from 68 to 1,073 microSv. Medium-FOV CBCT E(2007) ranged from 69 to 560 microSv, whereas a similar-FOV MDCT produced 860 microSv. The E(2007) calculations were 23% to 224% greater than E(1990). CONCLUSIONS The 2007 recommendations of the ICRP, which include salivary glands, extrathoracic region, and oral mucosa in the calculation of effective dose, result in an upward reassessment of fatal cancer risk from oral and maxillofacial radiographic examinations. Dental CBCT can be recommended as a dose-sparing technique in comparison with alternative medical CT scans for common oral and maxillofacial radiographic imaging tasks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Cone Beam CT Evaluation of the Bony Changes in the Temporomandibular Joint and the Association with the Clinical Symptoms of Temporomandibular Joint Disorders

Introduction: Temporomandibular joint (TMJ) disorders are among the most prevalent abnormalities of the jaw, which affect the masticatory system, including the muscles, TMJ, and tendons. Clinical examination alone cannot determine the cause of temporomandibular disorder (TMD). In most cases, the cause of TMD and a proper treatment plan are determined based on imaging modalities. The present stu...

متن کامل

Cone beam computed tomography: basics and applications in dentistry

The introduction of cone beam computed tomography (CBCT) devices, changed the way oral and maxillofacial radiology is practiced. CBCT was embraced into the dental settings very rapidly due to its compact size, low cost, low ionizing radiation exposure when compared to medical computed tomography. Alike medical CT, 3 dimensional evaluation of the maxillofacial region with minimal distortion is o...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

Incidental dentomaxillofacial findings on cone beam computed tomography images of Iranian population

BACKGROUND AND AIM: The present study aimed to assess the nature and prevalence of incidental findings in cone beam computed tomography (CBCT) images of oral and maxillofacial patients. METHODS: In this cross-sectional study, 773 CBCT samples were retrieved from archives of a private oral and maxillofacial radiology center. Any findings that were not related to the reason of CBCT request was re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics

دوره 106 1  شماره 

صفحات  -

تاریخ انتشار 2008