Calibration of a Quadrupole Gas Analyzer Using a Reference Gas*

نویسنده

  • Kimo M. Welch
چکیده

A quadrupole gas analyzer system was calibrated for the gases H2, He, N2, 02, A, and Xe. The procedure involved first calibrating the system for argon, as the reference gas. This was done using conventional techniques. A mixture of the above gases was then introduced into the system to be calibrated. The system configuration was such that the ratio of the partial pressures of each of the test gases with respect to the reference gas would be unity in the absence of sorption processes within the test envelope. Near ideal calibration characteristics of the quadupole combining the properties of the ion injection system, mass filter, and ion collector are given for Hz, He, N2, and Xe. The indicated partial pressure of oxygen was, under most test conditions, 10 -3 to 10 -2 times that of the reference gas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of Single Point Monitors for Measuring Aerial Ammonia and Hydrogen Sulfide

Performance of 43-44 Single Point Monitors (SPMs) was evaluated for measuring aerial ammonia (NH3, 0-30 ppm) and hydrogen sulfide (H2S, 0-90 ppb) under laboratory and field conditions. Calibration gas or sample air with various levels of moisture content or dew-point temperature (tdp) and gas concentrations were introduced simultaneously to the SPMs and a reference gas analyzer – chemiluminesce...

متن کامل

Fast Wavelength Calibration Algorithm for Optical Spectrum Analyzers

In this paper an algorithm for fast wavelength calibration of Optical Spectrum Analyzers (OSAs) using low power reference gas spectra is proposed. In existing OSAs a reference spectrum with low noise for precise detection of the reference extreme values is needed. To generate this spectrum costly hardware with high optical power is necessary. With this new wavelength calibration algorithm it is...

متن کامل

Noise Performance Optimization of a Fast Wavelength Calibration Algorithm for OSAs

A new fast correlation algorithm for calibrating the wavelength of Optical Spectrum Analyzers (OSAs) was introduced in [1]. The minima of acetylene gas spectra were measured and correlated with saved theoretical data [2]. So it is possible to find the correct wavelength calibration data using a noisy reference spectrum. First tests showed good algorithmic performance for gas line spectra with h...

متن کامل

Calibration effects during natural gas analysis using a quadrupole mass spectrometer

Quadrupole mass spectrometry (QMS) is regularly used for online monitoring of gaseous systems. With the advent of miniature QMS, it is possible to apply this capability to the analysis of gas samples extracted from drilling mud during exploration and development of oil and gas fields. QMS analysis can provide rapid compositional data for a range of hydrocarbons, providing early recognition of p...

متن کامل

Real-Time Continuous Glucose Monitoring Shows High Accuracy within 6 Hours after Sensor Calibration: A Prospective Study

Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS) has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1969