Primary results from the SmartDelay determined AV optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy (SMART-AV) trial: a randomized trial comparing empirical, echocardiography-guided, and algorithmic atrioventricular delay programming in cardiac resynchronization therapy.

نویسندگان

  • Kenneth A Ellenbogen
  • Michael R Gold
  • Timothy E Meyer
  • Ignacio Fernndez Lozano
  • Suneet Mittal
  • Alan D Waggoner
  • Bernd Lemke
  • Jagmeet P Singh
  • Francis G Spinale
  • Jennifer E Van Eyk
  • Jeffrey Whitehill
  • Stanislav Weiner
  • Maninder Bedi
  • Joshua Rapkin
  • Kenneth M Stein
چکیده

BACKGROUND one variable that may influence cardiac resynchronization therapy response is the programmed atrioventricular (AV) delay. The SmartDelay determined av optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy (SMART-AV) trial prospectively randomized patients to a fixed empirical AV delay (120 milliseconds), echocardiographically optimized AV delay, or AV delay optimized with SmartDelay, an electrogram-based algorithm. METHODS AND RESULTS a total of 1014 patients (68% men; mean age, 66 ± 11 years; mean left ventricular ejection fraction, 25 ± 7%) who met enrollment criteria received a cardiac resynchronization therapy defibrillator, and 980 patients were randomized in a 1:1:1 ratio. All patients were programmed (DDD-60 or DDDR-60) and evaluated after implantation and 3 and 6 months later. The primary end point was left ventricular end-systolic volume. Secondary end points included New York Heart Association class, quality-of-life score, 6-minute walk distance, left ventricular end-diastolic volume, and left ventricular ejection fraction. The medians (quartiles 1 and 3) for change in left ventricular end-systolic volume at 6 months for the SmartDelay, echocardiography, and fixed arms were -21 mL (-45 and 6 mL), -19 mL (-45 and 6 mL), and -15 mL (-41 and 6 mL), respectively. No difference in improvement in left ventricular end-systolic volume at 6 months was observed between the SmartDelay and echocardiography arms (P=0.52) or the SmartDelay and fixed arms (P=0.66). Secondary end points, including structural (left ventricular end-diastolic volume and left ventricular ejection fraction) and functional (6-minute walk, quality of life, and New York Heart Association classification) measures, were not significantly different between arms. CONCLUSIONS neither SmartDelay nor echocardiography was superior to a fixed AV delay of 120 milliseconds. The routine use of AV optimization techniques assessed in this trial is not warranted. However, these data do not exclude possible utility in selected patients who do not respond to cardiac resynchronization therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy.

OBJECTIVES The purpose of this study was to determine if AV delay optimization with continuous-wave Doppler aortic velocity-time integral (VTI) is clinically superior to an empiric program in patients treated with cardiac resynchronization therapy (CRT) for severe heart failure. BACKGROUND The impact of AV delay programming on clinical outcomes associated with CRT is unknown. METHODS A rand...

متن کامل

Cardiac resynchronization therapy during rest and exercise: comparison of two optimization methods

AIMS Optimal exercise programming of cardiac resynchronization therapy (CRT) devices is unknown. We aimed to: (i) investigate variations in optimal atrioventricular (AV) and interventricular (VV) delays from rest to exercise, assessed by both echocardiography and an automated intracardiac electrogram (IEGM) method; (ii) evaluate the acute haemodynamic impact of CRT optimization performed during...

متن کامل

Feasibility of a novel atrioventricular delay optimization method using transmitral and pulmonary venous flow in patients with sequential ventricular pacing or cardiac resynchronization therapy

BACKGROUND Although several echo-Doppler methods were proposed to optimize atrioventricular (AV) delay in patients with sequential ventricular pacing, "echo-guided" AV optimization has not been widely adopted clinically. A combination of trasmitral flow (TMF) and pulmonary venous flow (PVF) measurements may be beneficial to further optimize AV delay to achieve better cardiac function. The aim o...

متن کامل

Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization.

An optimized atrioventricular (AV) interval can maximize the benefits of cardiac resynchronization therapy (CRT). If programmed poorly, it may curtail beneficial effects of CRT. AV optimization will not convert non-responder to responder, but may convert under-responder to improved status. There are many echocardiographic techniques for AV optimization but there is no universally accepted gold ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 122 25  شماره 

صفحات  -

تاریخ انتشار 2010