Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI.
نویسندگان
چکیده
Electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are now being combined to analyze brain function. Confounding the EEG signal acquired in the MR environment is a ballistocardiogram artifact (BA), which is predominantly caused by cardiac-related body movement. The objective of this study was to develop and evaluate a method for reducing these MR-induced artifacts to retrieve small auditory event-related potentials (ERPs) from EEG recorded during fMRI. An algorithm for BA reduction was developed that relies on timing information obtained from simultaneous electrocardiogram (ECG) recordings and subsequent creation of an adaptive BA template. The BA template is formed by median-filtering 10 consecutive BA events in the EEG signal. The continuously updated template is then subtracted from each BA in the EEG. The auditory ERPs are obtained through signal averaging of the remaining EEG signal. Experimental and simulated ERP data were estimated to assess effectiveness of the BA reduction. Simulation showed that the algorithm reduced BA without significantly altering the morphology of a signal periodically inserted in the EEG. Auditory ERP data, obtained in a 1.5-T scanner during a passive auditory oddball paradigm and processed with the BA reduction algorithm, were comparable to data recorded in a mock scanner outside the magnetic field with the same experimental paradigm. It is concluded that through adequate reduction of the BA, relatively small auditory ERPs can be acquired in the MR environment.
منابع مشابه
Moving GLM ballistocardiogram artifact reduction for EEG acquired simultaneously with fMRI.
OBJECTIVE Simultaneous acquisition of electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) enables studies of brain activity at both high temporal and high spatial resolution. However, EEG acquired in a magnetic field is contaminated by ballistocardiogram (BKG) artifact. The most commonly used method of BKG artifact reduction, averaged artifact subtraction (AAS), was not ...
متن کاملBallistocardiogram artifacts in simultaneous EEG- fMRI acquisitions
The simultaneous acquisition of electroencephalograpy (EEG) and functional magnetic resonance imaging (fMRI) data is very promising for the study of cognitive processes and disorders but causes severe artifacts in the EEG. In this study the aim is to remove the ballistocardiogram artifact, caused by cardiac pulse-related movements of the electrodes in the magnetic field. For this purpose a meth...
متن کاملReal-time EEG artifact correction during fMRI using ICA
BACKGROUND Simultaneous acquisition of EEG and fMRI data results in EEG signal contamination by imaging (MR) and ballistocardiogram (BCG) artifacts. Artifact correction of EEG data for real-time applications, such as neurofeedback studies, is the subject of ongoing research. To date, average artifact subtraction (AAS) is the most widespread real-time method used to partially remove BCG and imag...
متن کاملInternal ventilation system of MR scanners induces specific EEG artifact during simultaneous EEG-fMRI
During simultaneous EEG-fMRI acquisition, the EEG signal suffers from tremendous artifacts caused by the scanner "environment". Particularly, gradient artifacts and the ballistocardiogram have been well characterized, along with methods to eliminate them. Here, we describe another systematic artifact in the EEG signal, which is induced by the internal ventilation system of Siemens TRIO and VERI...
متن کاملRecording Visual Evoked Potentials and Auditory Evoked P300 at 9.4T Static Magnetic Field
Simultaneous recording of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) has shown a number of advantages that make this multimodal technique superior to fMRI alone. The feasibility of recording EEG at ultra-high static magnetic field up to 9.4 T was recently demonstrated and promises to be implemented soon in fMRI studies at ultra high magnetic fields. Recording ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2004