Material Evaluation: Self Damping Wire SD/ACSR Conductor Failures

نویسندگان

  • Daniel F. Weyer
  • Jeffrey E. Shield
چکیده

Power District (NPPD) implemented an inspection program to determine the extent of condition for this type of widely used conductor. Other companies which have had related issues with similar types of corrosion have simply replaced their existing insignificant miles of conductor; however NPPD transmission system includes over 2000 miles of this particular conductor. Throughout 2012, many other conductor spans were discovered with either broken or missing steel wire in the bundled conductor. Transmission line splices are installed every 15-20 spans, with failures being located in a span containing a splice. NPPD worked with Kinectrics to complete electromagnetic field inspections for three days in 2013, with retesting performed in 2015. Throughout this inspection of 54 spans of conductor, 36 were found to have some level of deterioration/corrosion ranging from marginal (5) to fair (1) to good (30). Over 80% of the corrosion noted in the report was found on a conductor span containing a splice; only 45% of the spans tested contain a splice. All of the failures occurred in spans where a compression sleeve or compression dead-end was present. In all cases, only the steel core broke internal to trapezoidal aluminum wire layers. The results of the inspection indicated that there is a notable amount corrosion in more than 50% of the spans inspected, mainly located in the middle 300 feet of the span. The corrosion is " marginal " in a few locations, but generally not indicative of an acute problem. Removal of spans testing " marginal " occurred in April 2015, along with the physical evaluation of the conductor validating the results of the electromagnetic inspection tool. Broken strands were found in all of the tested conductors scored as " marginal " following removal 2 years after initial testing. None of the conductors were rated as poor, which would indicate no imminent failures exist. Since none of these localized areas were in poor condition, it could be several years before more frequent findings of broken wire and related problems are observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On Mechanical Waves Along Aluminum Conductor Steel Reinforced (ACSR) Power Lines

The propagation of elastic waves along composite wire rope is considered. The rope is modeled as co-axial layers of cylindrically anisotropic material. Simple kinematical assumptions lead to a ‘‘rod theory’’ for the wire rope, consisting of three coupled onedimensional wave equations. Solutions of these equations are found. Results for a particular aluminum conductor steel reinforced (ACSR) con...

متن کامل

Calculation of Stray Capacitances of MCG Coil include One Turn, Single-Layer and Conductor Wire Filaments in Rectangular form

This paper presents a new method called vespiary regular hexagonal (VRH) model in order to calculate parasitic capacitance between conductor wire filaments of one turn of coil (OTC) and between conductor wire filaments and liner and also total capacitance of one turn of the helix magneto flux cumulative generator (MCG) coil include single-layer conductor wire filaments in form of rectangular cr...

متن کامل

EVALUATION OF POWER LINE CABLE FATIGUE PARAMETERS BASED ON MEASUREMENTS ON A LABORATORY CABLE TEST SPAN S.Guérard

The present paper describes experiments carried out on IREQ 1 laboratory cable test bench. Test span arrangement is a 63.15m cable span with termination ends designed so as to minimize energy dissipation. A shaker provides a vertical alternating force to the conductor. During the experiments, a maximum of information on mode shape is collected: location of nodes, antinode amplitude of vibration...

متن کامل

Stability of Superconducting Wire in Magnetic Field

A fundamental experiment was carried out to study the motion of superconducting wire under the influence of electromagnetic force. Experiments were conducted at 4.2 K by varying the experimental conditions such as applied tension to test superconducting wire, insulating material used at the interface of superconducting wire and base material. The experimental method and the test results are rep...

متن کامل

Eddy Current Damping in Structures

When a conductive material is subjected to a time-varying magnetic flux, eddy currents are generated in the conductor. These eddy currents circulate inside the conductor generating a magnetic field of opposite polarity as the applied magnetic field. The interaction of the two magnetic fields causes a force that resists the change in magnetic flux. However, due to the internal resistance of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016