Three-Tesla Magnetic Resonance and Computed Tomography Imaging in Three-Dimensional Conformal Radiotherapy for Localized Prostate Cancer
نویسندگان
چکیده
Aims and background: we evaluate CT-3Tesla MRI fusion in conformal radiotherapy for localized prostate cancer.Methods: 18 consecutive patients underwent a 3T MRI scan under radiotherapy planning conditions, after the CT scan. Bowel and bladder preparation were prescribed. CT and MR images were automatically fused; prostate and seminal vesicles were contoured on CT and on MRI, organs at risk were defined on CT-MRI fusion. Late rectal and sexual toxicity, differences in target volume between MRI and CT and differences in rectal and penile bulb dose distribution based on CT only or on CT-MRI fusion were evaluated.Results: one patient experienced a late rectal toxicity; no patient had sexual toxicity. The difference between the mean MRI and CT target volumes was statistically significant (p = 0.0001 paired Student’s t-test). The dose-volume histogram (DVH) analysis shows a significant reduction of the dose received by the rectum and the penile bulb in MRI-plans compared to CT-plans.Conclusions: 3 Tesla MRI scan under radiotherapy planning conditions along with bowel preparation significantly improves the definition of the target volume sparing normal tissue irradiation.
منابع مشابه
Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma
Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...
متن کاملOptimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملDefinitive 3D-CRT for clinically localized prostate cancer: modifications of the clinical target volume following a prostate MRI and the clinical benefits
PURPOSE To evaluate the modifications of the tumor stage and clinical target volume following a prostate magnetic resonance imaging (MRI) to evaluate the tumor (T) staging, and the clinical benefits for prostate cancer. METHODS A total of 410 patients with newly diagnosed and clinically localized prostate cancer were retrospectively analyzed. The patients were treated with definitive three-di...
متن کامل