Evaluating the accuracy of an aneroid sphygmomanometer in a clinical trial setting.

نویسندگان

  • Yong Ma
  • Marinella Temprosa
  • Sarah Fowler
  • Ronald J Prineas
  • Maria G Montez
  • Janet Brown-Friday
  • Mary L Carrion-Petersen
  • Tracy Whittington
چکیده

BACKGROUND The mercury sphygmomanometer, the "gold" standard for blood pressure measurements, has been gradually phased out in many institutions because of environmental concerns. Our on-going clinical trial compared the use of mercury vs. aneroid sphygmomanometers, before implementing a study-wide transition to the aneroid sphygmomanometer. METHODS The Diabetes Prevention Program Outcomes Study (DPPOS) studied the accuracy of the Welch Allyn Tycos 767-Series Mobile aneroid sphygmomanometer from 20 March 2006 to 21 June 2006 at multiple clinic centers. We compared readings from 997 participants in 24 clinic centers using both mercury and aneroid sphygmomanometers. RESULTS The study found no statistically significant difference for systolic blood pressure (SBP) (P > 0.05) and a small but significantly (P < 0.0001) lower (0.8 mm Hg) reading for diastolic blood pressure (DBP) using the aneroid sphygmomanometer. Regression analysis of aneroid vs. mercury showed regression lines (Y = 4.8 + 0.96X for SBP, Y = 3.1 + 0.95X for DBP) slightly but statistically significantly different from the line of equality (P < 0.001). Participants' age, sex, race/ethnicity, body mass index, blood pressure, and clinical center together explain about 8-10% of the variation of the difference between readings from the two sphygmomanometers. Based on the above result, on 1 August 2006, DPPOS clinics began the conversion from mercury to aneroid sphygmomanometers. CONCLUSIONS The Welch Allyn Tycos 767-Series Mobile Aneroid model 7670-04 tested in this validation study can be used to replace mercury model in clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alternatives to the mercury sphygmomanometer.

The mercury sphygmomanometer was introduced over 100 years ago. Mercury, however, is a potent human neurotoxin. An international effort has developed to eliminate health-care sources of mercury--the thermometer and sphygmomanometer--and replace them with less toxic alternatives. There is concern regarding the accuracy of these alternative devices. We conducted a literature review of articles pu...

متن کامل

Validation of Heine Gamma G7 (G5) and XXL-LF aneroid devices for blood pressure measurement.

OBJECTIVE To determine the accuracy of the Gamma G7 (and G5 model) and XXL-LF aneroid sphygmomanometers developed by the Heine Company. DESIGN Device evaluations were performed using the new protocol of the European Society of Hypertension. Monitor performance was assessed in relation to participants' sex, age, arm circumference, and systolic and diastolic blood pressures. METHODS The two s...

متن کامل

Validation of Missouri aneroid sphygmomanometer to measure blood pressure in patients with cancer.

BACKGROUND Auscultatory mercury sphygmomanometers to measure blood pressure (BP) have been banned from health services because of risk of pollution and environmental accidents with mercury. Aneroid appliances could be an alternative. OBJECTIVE To validate the Missouri aneroid device for blood pressure measurement in cancer patients according to the protocol of the European Society of Hyperten...

متن کامل

Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study.

BACKGROUND Previous studies identified worrying levels of sphygmomanometer inaccuracy and have not been repeated in the era of digital measurement of blood pressure. AIM To establish the type and accuracy of sphygmomanometers in current use. DESIGN AND SETTING Cross-sectional, observational study in 38 Oxfordshire primary care practices. METHOD Sphygmomanometers were evaluated between 50 ...

متن کامل

Assessing blood pressure accuracy of an aneroid sphygmomanometer in a national survey environment.

BACKGROUND The "gold standard" employed for obtaining blood pressure (BP) for all the National Health and Nutrition Examination Surveys (NHANES) has been the mercury sphygmomanometer (HgS). Because of environmental concerns, there is a need to explore an alternative to HgS. METHODS We compared the accuracy of the Welch Allyn 767 wall aneroid sphygmomanometer (AnS) to the HgS in children and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of hypertension

دوره 22 3  شماره 

صفحات  -

تاریخ انتشار 2009