Evaluation of noninvasive blood pressure monitoring devices Spacelabs 90202 and 90207 versus resting and ambulatory 24-hour intra-arterial blood pressure.
نویسندگان
چکیده
This study evaluated the accuracy of blood pressure values provided by the Spacelabs 90202 and 90207 devices in comparison with intra-arterial recording in 19 subjects at rest and in nine subjects in ambulatory conditions (Oxford method). At rest Spacelabs monitors reflected intra-arterial systolic blood pressure values very closely but overestimated to a considerable extent intra-arterial diastolic blood pressure (Spacelabs-intra-arterial differences, -0.8 +/- 9.2, NS, and 9.1 +/- 8.8 mm Hg, p less than 0.01, for systolic and diastolic blood pressures, respectively). In ambulatory conditions Spacelabs-intra-arterial average differences in 24-hour values were +0.4 +/- 5.1 mm Hg for systolic blood pressure (NS) and +14.0 +/- 2.9 mm Hg for diastolic blood pressure (p less than 0.01) when group data were considered. The performance of both Spacelabs devices was worse when assessed in individual subjects or for each hourly interval. In spite of these differences between noninvasive and intra-arterial absolute blood pressure values, however, Spacelabs 90202 and 90207 monitors were able to faithfully reflect directional hour-to-hour changes in intra-arterial blood pressure (chi 2 = 18.2 and chi 2 = 23.1 for systolic and diastolic blood pressures, respectively, p less than 0.01). No differences were found between the performance of the two Spacelabs devices. Thus, although the absolute accuracy of blood pressure values provided by these monitors in ambulatory subjects is still limited, they seem to be suitable for studies aimed at assessing 24-hour blood pressure profiles quantitatively as well as qualitatively.
منابع مشابه
Ambulatory blood pressure measurement in the diagnosis and management of hypertension.
Before the diagnostic potential of 24-hour non-invasive BP measurement can be assessed, the accuracy of ambulatory recorders must be established, and normal reference values determined. The accuracy criteria of four ambulatory BP measuring systems (the SpaceLabs 90207, the Novecor DIASYS 200, the Takeda TM-2420 and the Del Mar Avionics Pressurometer IV) have been assessed according to the Briti...
متن کاملTwenty-four-hour ambulatory blood pressure monitoring: a review of validation data.
As the clinical applications for 24-h ambulatory blood pressure monitoring expand, market demands increase, and there are now at least 13 manufacturers producing elaborate and expensive systems for recording 24-h ambulatory pressures. It is often difficult to assess the accuracy and performance characteristics of these devices and failure to standardize validation makes it difficult to compare ...
متن کاملState of the market. A review of ambulatory blood pressure monitoring devices.
The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any valid...
متن کاملEvaluation of the SpaceLabs 90202 non-invasive ambulatory recorder according to the AAMI Standard and BHS criteria.
The SpaceLabs 90202, a non-invasive ambulatory blood pressure recorder for the measurement of 24 hr blood pressure, was assessed according to the standard of the Association for the Advancement of Medical Instrumentation (AAMI) and the grading criteria of the British Hypertension Society (BHS) protocol were applied to the results. Two observers measured BP simultaneously in the same arm with th...
متن کاملDo SpaceLabs ambulatory non-invasive blood pressure recorders measure blood pressure consistently over several years use?
OBJECTIVE To assess the measurement consistency of SpaceLabs ambulatory recorders (Spacelabs, Washington, USA) that are in regular use. METHODS A total of 14 SpaceLabs 90207 and one 90217 ambulatory recorders were tested for measurement consistency using the Dynatech CuffLink (Dynatech, Nevada, USA), a commercially available non-invasive blood pressure (NIBP) simulator. The NIBP recorders wer...