End-to-side nerve repair using fibrin glue in rats.

نویسندگان

  • Daniel Nunes e Silva
  • Julice Coelho
  • Fabrício de Oliveira Frazílio
  • Alexandre Nakao Odashiro
  • Paulo de Tarso Camillo de Carvalho
  • Elenir Rose Jardim Cury Pontes
  • André Ferrão Vargas
  • Marcelo Rosseto
  • Andréia Brochado Antoniolli da Silva
چکیده

PURPOSE To evaluate axonal regeneration after end-to-side nerve repair with fibrin glue in rats. METHODS Forty-five Wistar rats were divided into three groups: group A (n=15), were not submitted to surgery (control group); group B (n=15) were submitted to fibular transection without repair; and group C (n=15), were submitted to fibular transection with end-to-side nerve anastomosis using fibrin glue, in the lateral surface of an intact tibial nerve. The three groups were submitted to walking track (30 and 90 days) and posterior morphometrical analysis (90 days). RESULTS The functional tests demonstrated that there was no difference in the walking track during the study in group A (p>0.05). The group B had walking pattern impairment in the two tests (p>0.05). The group C had walking pattern impairment in the first test, with important recovery in the second test (p<0.05). The morphometrical assessment revealed significantly higher number of regenerated mielinates axons in group C, compared to group B (p<0.05). CONCLUSION The end-to-side nerve repair with fibrin glue shows axonal recovery, demonstrated through functional and morphometrical ways in rats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nerve growth factor with fibrin glue in end-to-side nerve repair in rats.

PURPOSE To determine the effects of end-to-side nerve repair performed only with fibrin glue containing nerve growth in rats. METHODS Seventy two Wistar rats were divided into six equal groups: group A was not submitted to nerve section; group B was submitted to nerve fibular section only. The others groups had the nerve fibular sectioned and then repaired in the lateral surface of an intact ...

متن کامل

Fibrin glue repair leads to enhanced axonal elongation during early peripheral nerve regeneration in an in vivo mouse model

Microsurgical suturing is the gold standard of nerve coaptation. Although literature on the usefulness of fibrin glue as an alternative is becoming increasingly available, it remains contradictory. Furthermore, no data exist on how both repair methods might influence the morphological aspects (arborization; branching) of early peripheral nerve regeneration. We used the sciatic nerve transplanta...

متن کامل

Comparison of nerve repair with end to end, end to side with window and end to side without window methods in lower extremity of rat

  Abstract   Background : Although, different studies on end-to-side nerve repair, results are controversial. The importance of this method in case is unavailability of proximal nerve. In this method, donor nerves also remain intact and without injury. In compare to other classic procedures, end-to-side repair is not much time consuming and needs less dissection. Overall, the previous studies i...

متن کامل

Histopathological effects of fibrin glue on penile fracture in a rat model.

PURPOSE To evaluate both histopathological effects and potential clinical application of fibrin glue on the penile cavernosal tissue. METHODS Experimental penile fracture was formed by incising from the proximal dorsal side of the penis in 32 Wistar Albino rats. The rats were randomly assigned to four main groups of eight animals each. In the control group, the incision was not repaired and i...

متن کامل

Preliminary investigation of a polyethylene glycol hydrogel "nerve glue"

BACKGROUND Polyethylene glycol (PEG) hydrogel is a biocompatible semi-adherent gel like substance that can potentially augment nerve repair much like a fibrin sealant. Potential advantages of this substance include fast preparation and set up time, as well as adhesion inhibiting properties. The purpose of this study was to perform an initial evaluation of PEG hydrogel in this application. MET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta cirurgica brasileira

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2010