A duplicated spinous process of the C7 vertebra.
نویسندگان
چکیده
Normally the 7th cervical vertebra (C7) has a long non-bifid spine. A bifid spine is a feature of typical cervical vertebrae such as C3--C6. In contrast to past studies, which have described a bifid spine in the C3--C6 cervical vertebrae, this study is a report on the presence of a duplicated spinous process in the C7 vertebra with an intervening space. The presence of such anomalies may be associated with other congenital anomalies and needs a careful and thorough clinical approach. This is an extremely rare finding which may be of clinical interest to radiologists, neurologists, orthopaedic surgeons, anthropologists and forensic personnel. The present case report describes the anatomical details in the bone specimen along with its radiological picture in a case of a duplicated spinous process of the C7 vertebra.
منابع مشابه
Feasibility Study of Free-Hand Technique for Pedicle Screw Insertion at C7 without Fluoroscopy-Guidance
STUDY DESIGN Retrospective interventional study. PURPOSE To introduce a free-hand pedicle screw (PS) insertion technique without fluoroscopic guidance in the C7 vertebra and evaluate the procedure's feasibility and radiologic outcomes. OVERVIEW OF LITERATURE Although PS insertion at C7 has been recognized as a critical procedure in posterior cervical fusion surgery, conventional techniques ...
متن کاملThe Incidence of Bifid C7 Spinous Processes
For posterior cervical surgery, if the operation only involves the lower cervical area, counting from C2 is impractical and the level may not be visible on X-rays. In such cases, we usually place a marker at the top of the incision and also rely on the size and monofid shape of the C7 spinous process. Relying on the C7 morphology, however, we initially instrumented the wrong levels in a case wh...
متن کاملReview of the Literature on Anatomical Variations of the Trapezius Muscle
The trapezius muscle originates on the occipital bone, nuchal ligament, spinous process of the 7th cervical vertebra (C7) and all of the thoracic vertebrae (Figure 1). It has three parts. The superior portion (descending fibers) terminates on the posterior margin and superior side of the lateral third of the clavicle. The transverse portion (middle fibers) terminates on the medial margin of the...
متن کاملPreserving the C7 spinous process in laminectomy combined with lateral mass screw to prevent axial symptom
BACKGROUND Preserving the C7 spinous process during cervical laminoplasty has been reported to prevent axial symptom. Some patients underwent laminectomy and fixation developed the symptom. The objective of this article was to investigate whether axial symptom can be reduced by preserving the C7 spinous process during cervical laminectomy and fixation with lateral mass screw. METHODS Between ...
متن کاملSurgical anatomy of the nuchal muscles in the posterior cervicothoracic junction; The relationship between the length of the C6 spinous process and anatomy of the nuchal muscles
INTRODUCTION In previous studies, it was reported that the incidence of postoperative axial pain was lower in C3-C6 laminoplasty than in C3-C7 laminoplasty, emphasizing the effectiveness of the former procedure where discission of the nuchal muscles that are attached to the C7 spinous process is avoided 1), . However, there have been no detailed anatomic studies of the attachment of the nuchal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Folia morphologica
دوره 64 2 شماره
صفحات -
تاریخ انتشار 2005