Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography.

نویسندگان

  • F Chirillo
  • A Bruni
  • G Balestra
  • C Cavallini
  • Z Olivari
  • J D Thomas
  • P Stritoni
چکیده

OBJECTIVE To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tested prospectively in a further 84 patients (test group). SETTING Three tertiary referral centres. INTERVENTIONS Flow velocities in grafts were recorded at rest and during hyperaemia induced by dipyridamole (0.56 mg/kg/4 min), under the guidance of transthoracic colour Doppler flow mapping. Findings on transthoracic Doppler were compared with angiography. MAIN OUTCOME MEASURES Feasibility of identifying open grafts by Doppler and diagnostic accuracy for Doppler detection of significant (>/= 70%) graft stenosis. RESULTS In the test group the identification rate for mammary artery grafts was 100%, for saphenous vein grafts to left anterior descending coronary artery 91%, for vein grafts to right coronary artery 96%, and for vein grafts to circumflex artery 90%. Coronary flow reserve (the ratio between peak diastolic velocity under hyperaemia and at baseline) of < 1.9 (95% confidence interval 1.83 to 2.08) had 100% sensitivity, 98% specificity, 87.5% positive predictive value, and 100% negative predictive value for mammary artery graft stenosis. Coronary flow reserve of < 1.6 (95% CI 1.51 to 1.73) had 91% sensitivity, 87% specificity, 85.4% positive predictive value, and 92.3% negative predictive value for significant vein graft stenosis. CONCLUSIONS Transthoracic Doppler can provide non-invasive assessment of CABG patency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transthoracic Doppler echocardiography of the left internal mammary artery graft.

Assessment of the left internal mammary artery (LIMA) graft patency currently requires invasive investigation through coronary angiography. In the last years the successful application of noninvasive Doppler spectrum analysis has been reported for patency assessment of the LIMA graft after myocardial revascularization. Echocardiography is considered to be a sensitive noninvasive screening modal...

متن کامل

Left internal mammary artery graft dysfunction diagnosed by transthoracic Doppler echocardiography. A report of two cases.

Transthoracic Doppler echocardiography (TDE) is a non-invasive and easy reproducible method to assess the left internal mammary artery (LIMA) graft patency after coronary artery bypass graft surgery (CABG). LIMA graft dysfunction is rare, its rate being 10% at 10 to 15 years after revascularization. The most common cause of graft dysfunction is the competitive flow with the native coronary arte...

متن کامل

Intraoperative flow measurements in gastroepiploic grafts using pulsed Doppler.

OBJECTIVE The patency of a pedicled right gastroepiploic artery (RGEA) graft can be compromised by intraoperative twists, kinks or spasms. Therefore, a systematic flow assessment was made in RGEA grafts and was compared with similar measurements made in other types of bypass conduits. METHODS Intraoperative pulsed Doppler flowmeter measurements obtained in a series of 556 consecutive patients...

متن کامل

[Anomalous origin of right coronary artery].

Aroutine transthoracic echocardiogram (TTE) was performed in a 72-year-old woman with signs and symptoms of heart failure. The 2D TTE images revealed an enlarged right coronary artery (RCA) with reverse flow draining into the pulmonary trunk and the presence of dilated septal vessels (Figure 1). Coronary angiography and MRI confirmed the previous echocardiographic findings (Figures 2 to 4). Acc...

متن کامل

Fractional flow reserve of pedicled internal thoracic artery and saphenous vein grafts 6 months after bypass surgery.

BACKGROUND Although the internal thoracic artery was proven superior to saphenous vein graft in long-term patency, it is thought to be a more resistive conduit than the vein graft. Moreover, patency studies comparing both left and right internal thoracic arteries have provided results favoring the former. Fractional flow reserve is an established functional index of coronary blood flow. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 86 4  شماره 

صفحات  -

تاریخ انتشار 2001