Metal-coated microfluidic channels: An approach to eliminate streaming potential effects in nano biosensors.

نویسندگان

  • Jieun Lee
  • Mathias Wipf
  • Luye Mu
  • Chris Adams
  • Jennifer Hannant
  • Mark A Reed
چکیده

We report a method to suppress streaming potential using an Ag-coated microfluidic channel on a p-type silicon nanowire (SiNW) array measured by a multiplexed electrical readout. The metal layer sets a constant electrical potential along the microfluidic channel for a given reference electrode voltage regardless of the flow velocity. Without the Ag layer, the magnitude and sign of the surface potential change on the SiNW depends on the flow velocity, width of the microfluidic channel and the device's location inside the microfluidic channel with respect to the reference electrode. Noise analysis of the SiNW array with and without the Ag coating in the fluidic channel shows that noise frequency peaks, resulting from the operation of a piezoelectric micropump, are eliminated using the Ag layer with two reference electrodes located at inlet and outlet. This strategy presents a simple platform to eliminate the streaming potential and can become a powerful tool for nanoscale potentiometric biosensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Method to Reduce Effects of Packet Loss in Video Streaming Using Multiple Description Coding

Multiple description (MD) coding has evolved as a promising technique for promoting error resiliency of multimedia system in real-time application programs over error-prone communicational channels. Although multiple description lattice vector quantization (MDCLVQ) is an efficient method for transmitting reliable data in the context of potential error channels, this method doesn’t consider disc...

متن کامل

Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these pro...

متن کامل

Removal of Malachite Green by Using Immobilized Glucose Oxidase Onto Silica Nanostructure-Coated Silver Metal-Foam

Enzymes Immobilization onto different types of the substrate could be helpful in various applicationsof biomedical devices and biosensors. Enzyme activity and stability could be affected by support andmethod of immobilization. In this study, the silver metal foam was successfully synthesized by thesoft-shell method and then was coated with silica. Then, glucose oxidase (GOx) immobilized on nonc...

متن کامل

Nanometal-decorated exfoliated graphite nanoplatelet based glucose biosensors with high sensitivity and fast response.

We report the novel fabrication of a highly sensitive, selective, fast responding, and affordable amperometric glucose biosensor using exfoliated graphite nanoplatelets (xGnPs) decorated with Pt and Pd nanoparticles. Nafion was used to solubilize metal-decorated graphite nanoplatelets, and a simple cast method with high content organic solvent (85 wt %) was used to prepare the biosensors. The a...

متن کامل

The Effect of Coinage Transition Metal (Cu, Ag, Au) Substitutions on Two-electron Redox Potential of Quinones

Quinones are a class of compounds which have widespread importance in chemistry, biology and medicine. Because of their appropriate performance in electron transferring rate, quinones are among the most applicable mediators in biosensors. Recently, the effects of different non-metal substitutions on redox potential of quinone have been investigated to design suitable mediators for different ele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2017