Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.
نویسندگان
چکیده
PURPOSE To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). SETTING Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Paris, France. DESIGN Evaluation of a diagnostic device. METHODS One eye of consecutive patients scheduled for cataract surgery was measured. Biometry was performed with the new biometer and the reference biometer. Comparisons were performed for AL, average K at 2.4 mm, ACD, IOL power calculations with the Haigis and SRK/T formulas, and postoperative predictability of the devices. A P value less than 0.05 was statistically significant. RESULTS The study enrolled 50 patients (mean age 72.6 years±4.2 SEM). There was a good correlation between biometers for AL, K, and ACD measurements (r=0.999, r=0.933, and r=0.701, respectively) and between IOL power calculation with the Haigis formula (r=0.972) and the SRK/T formula (r=0.981). The mean absolute error (MAE) in IOL power prediction was 0.42±0.08 diopter (D) with the new biometer and 0.44±0.08 D with the reference biometer. The MAE was 0.20 D with the Haigis formula and 0.19 with the SRK/T formula (P=.36). CONCLUSION The new PCI biometer provided valid measurements compared with the current gold standard, indicating that the new device can be used for IOL power calculations for routine cataract surgery. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Comparison of ocular biometry and intraocular lens power using a new biometer and a standard biometer.
PURPOSE To compare the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power obtained with a new optical biometer (AL-Scan) and a standard optical biometer (IOLMaster 500). SETTING Siriraj Hospital, Mahidol University, Bangkok, Thailand. DESIGN Prospective comparative study. METHODS Two independent operators measured eyes with cataract using both biometers....
متن کاملComparison of a new optical biometer and a standard biometer in cataract patients
BACKGROUND Cataract surgery is the most common surgical procedure in ophthalmology. Biometry data and accurate intraocular lens (IOL) calculations are very important in achieving the desired refractive outcomes. The aim of this study was to compare measurements using a new optical low coherence reflectometry (OLCR) biometer (OA-2000) and the gold standard partial coherence interferometry (PCI) ...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملAccuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation
PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...
متن کاملVisual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2014