Optical coherence tomography velocimetry of colloidal suspensions.
نویسندگان
چکیده
Optical coherence tomography velocimetry combined with a rheometer and optical modulation techniques provides increased sensitivity to the low shear rate motion of complex fluid systems. Optical modulation coupled with a new interferometer design yields improved signal to noise ratios and is demonstrated with optically opaque colloidal suspensions. Thus the measurable range of shear velocities with complex fluids can be as low as ∼40 μm s(-1), more than an order of magnitude improvement on the previous lower limit of ∼700 μm s(-1). Furthermore the apparatus demonstrates improved sensitivity to the measurement of velocity. The instrument was used to study two hard sphere colloidal systems, sterically stabilized PVP spheres of 1 μm radius and sterically stabilized polystyrene spheres of 600 nm radius, which display shear banding behavior due to shear induced concentration gradients. OCT velocimetry also allows the velocity fluctuations of the system to be quantified as a function of the distance across the rheometer gap to help classify underlying unsteady or turbulent phenomena.
منابع مشابه
OCT VELOCIMETRY OF COLLOIDAL SUSPENSIONS SOFT MATTER Optical Coherence Tomography Velocimetry of Colloidal Suspensions
Please note that technical editing may introduce minor changes to the text and/or graphics, which may alter content. The journal’s standard Terms & Conditions and the Ethical guidelines still apply. In no event shall the Royal Society of Chemistry be held responsible for any errors or omissions in this Accepted Manuscript or any consequences arising from the use of any information it contains. ...
متن کاملLocalized measurement of longitudinal and transverse flow velocities in colloidal suspensions using optical coherence tomography.
We report on localized measurement of the longitudinal and transverse flow velocities in a colloidal suspension using optical coherence tomography. We present a model for the path-length resolved autocorrelation function including diffusion and flow, which we experimentally verify. For flow that is not perpendicular to the incident beam, the longitudinal velocity gradient over the coherence gat...
متن کاملNew insight into rheology and flow properties of complex fluids with Doppler optical coherence tomography
Flow properties of complex fluids such as colloidal suspensions, polymer solutions, fiber suspensions and blood have a vital function in many technological applications and biological systems. Yet, the basic knowledge on their properties is inadequate for many practical purposes. One important reason for this has been the lack of effective experimental methods that would allow detailed study of...
متن کاملClinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Soft matter
دوره 10 41 شماره
صفحات -
تاریخ انتشار 2014