Electro-Fenton pretreatment for the improvement of tylosin biodegradability.

نویسندگان

  • Fatiha Ferrag-Siagh
  • Florence Fourcade
  • Isabelle Soutrel
  • Hamid Aït-Amar
  • Hayet Djelal
  • Abdeltif Amrane
چکیده

The feasibility of an electro-Fenton process to treat tylosin (TYL), a non-biodegradable antibiotic, was examined in a discontinuous electrochemical cell with divided cathodic and anodic compartments. Only 15 min electrolysis was needed for total tylosin degradation using a carbon felt cathode and a platinum anode; while 6 h electrolysis was needed to achieve high oxidation and mineralization yields, 96 and 88 % respectively. Biodegradability improvement was shown since BOD₅/COD increased from 0 initially to 0.6 after 6 h electrolysis (for 100 mg L(-1) initial TYL). With the aim of combining electro-Fenton with a biological treatment, an oxidation time in the range 2 to 4 h has been however considered. Results of AOS (average oxidation state) and COD/TOC suggested that the pretreatment could be stopped after 2 h rather than 4 h; while in the same time, the increase of biodegradability between 2 and 4 h suggested that this latter duration seemed more appropriate. In order to conclude, biological cultures have been therefore carried out for various electrolysis times. TYL solutions electrolyzed during 2 and 4 h were then treated with activated sludge during 25 days, showing 57 and 67% total organic carbon (TOC) removal, respectively, namely 77 and 88% overall TOC removal if both processes were considered. Activated sludge cultures appeared, therefore, in agreement with the assessment made from the analysis of physico-chemical parameters (AOS and COD/TOC), since the gain in terms of mineralization expected from increasing electrolysis duration appeared too low to balance the additional energy consumption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study on Trend of Biodegradability of Phenolic Compounds During Photo-Fenton Advanced Oxidation Process

Phenolic acids constitute a major group of pollutants which are recalcitrant to common biological treatment. In this study synthetic wastewater containing a mixture of p-coumaric and p-hydroxybenzoic acids was evaluated for photo-Fenton pretreatment. The changes in biodegradability (ratio of biochemical oxygen demand to total organic carbon (TOC)) and mineralization (TOC removal) were monitored...

متن کامل

بررسی تصفیه‌پذیری فاضلاب واقعی صنعت نساجی به وسیله فرایند تولید الکتروشیمیایی واکنش‌گر فنتون با استفاده از کاتد گرافیت فلت

Background and Objectives: Electro-Fenton process has been widely applied for dye removal from aqueous solution lately. Fenton's reagent is formed in the electrolysis medium through the simultaneous electrochemical reduction of O2 and Fe3+ to H2O2 and Fe2+ respectively on the cathode surface. In this paper, COD reduction potential and decolorization of real textile wastewater were evaluated...

متن کامل

بهبود تجزیه پذیری زیستی دی کلروفنل به کمک اکسیداسیون پیشرفته با معرف فنتون

Background and Aim: 2,4-Dichlorophenol (DCP) is a compound  generated in a variety of industrial processes and also by chlorine disinfection of water polluted with phenolic compounds . Dumping of DCP into the environment and water resources is of great concern because of the compound's intense odor and toxicity. DCP is very soluble and resistant to biodegradability so it cannot be removed throu...

متن کامل

Pharmaceutical Wastewater Chemical Oxygen Demand Reduction: Electro-Fenton, UV-enhanced Electro-Fenton and Activated Sludge

In this study, Chemical Oxygen Demand (COD) from a pharmaceutical wastewater (PhW) was reduced by several techniques such as electro-Fenton (EF), photo electro-Fenton (PEF) and activated sludge (AS) processes and the obtained data were compared with each other. The effects of several parameters such as pH, current density, H2O2/Fe2+ molar ratio, volume ratio of ...

متن کامل

Application of Electro-Fenton (EF) Process to the Removal of Pentachlorophenol from Aqueous Solutions

Pentachlorophenol (PCP) is a very hazardous compound which enters into the environment by industries such as refineries and petrochemicals. As its biological degradation is very slow, this use may cause the pollution of soils and groundwater; with the recent emergence of pentachlorophenol contamination as an important drinking water quality issue, finding an easy, economical, and useful method ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science and pollution research international

دوره 21 14  شماره 

صفحات  -

تاریخ انتشار 2014