Spectrophotometric Determination of Nickel with Chlorophosphonazo-III
نویسندگان
چکیده
The optimum conditions for spectrophotometric method for the determination of Ni with chlorophosphonazo-III (CPA-III) were established and the nickel content in water samples has been successfully determined. In a pH 5.5 acetic acid-sodium acetate buffer medium, CPA-III and Ni formed a 1:3 green blue complex and the maximum absorption wavelength of the complex is at 620 nm. Ni content in a range of 0.1~3.5 μg/mL and absorbance shows a good linear relationship. The apparent molar absorption coefficient of method is ε620nm = 1.40×10 L mol cm and the detection limit is 0.075 μg/mL.
منابع مشابه
Acta Technica Jaurinensis - Vol. 7. No. 1. (2014.)
A rapid and sensitive extractive spectrophotometric method has been developed for the determination of samarium using 0.04% Chlorophosphonazo III in 1 mol L hydrochloric acid media after extraction into isoamylalcohol. Absorbance was measured in 1-cm cell and the complex has a sensitive absorption peak at 667 nm. The complex of Sm(III)-Chlorophosphonazo III is formed instantly in organic phase ...
متن کاملA NEW SPECTROPHOTOMETRIC PROCEDURE FOR THE DETERMINATION OF NICKEL (11) USING 6-PHENYL-2,3-DIHYDRO-AS-TRIAZINE-3 –THIONE
A spectrophotometric procedure for the determination of Nickel (??) based on the complex formation with 6-phenyl-2, 3-dihydro-as-triazine-3-thione (PDTT) was developed. A yellow compound forms and is easily extractable by chloroform at pH>6. The mole ratio between Nickel (??) and PDTT is 1:4. The absorbance of the complex obeys Beer's law over the concentration range of 1-7 ug of Ni (??) pe...
متن کاملSimultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...
متن کاملSpectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
متن کاملSpectrophotometric Determination of Iron(II) with 5-Nitro-6-amino-1,10-phenanthroline
Gravimetric, titrimetric, polarographic, optical and radiochemical methods have been reported for the determination of iron(II) and (III). Numerous reagents have also been reported for the spectrophotometric determination of Fe(II); for example, thiocyanate, dipyridine, tripyridine and 1,10-phenanthroline. The 1,10phenanthroline family has been extended to the use of dihydroxy, dimethyl, nitro ...
متن کامل