Interactive Segmentation and Three-Dimension Reconstruction for Cone-Beam Computed-Tomography Images
نویسندگان
چکیده
We develop a novel interactive segmentation and 3-D visualization system for cone-beam computedtomography (CBCT) data in a personal computer environment. Its design includes both a new user interface to ease the interactive manual segmentation of the volume rendered and artifact-suppressing algorithms to improve the quality of CBCT images. Four pipelines of noise removal were carried out by applying threshold filter algorithm only and with additional smoothing algorithms (Gaussian filter, Median filter, Dilation and Erosion filter). The interactive intensity plot was implemented to allow user to manually identify each anatomic structure and view the instant feedback. The visual feedback necessary during 3-D segmentation was provided by a ray casting algorithm. Both orthodontic and non-orthodontic patients demonstrated that the system was able to minimize the artifacts caused by CBCT and metal appliances. Based on the feedback obtained from the dental experts, the interactive segmentation and 3-D reconstruction functions are found to be very helpful.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملمقایسه دقت توموگرافی سهبعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماریهای سینوس پارانازال
Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...
متن کاملIncidental dentomaxillofacial findings on cone beam computed tomography images of Iranian population
BACKGROUND AND AIM: The present study aimed to assess the nature and prevalence of incidental findings in cone beam computed tomography (CBCT) images of oral and maxillofacial patients. METHODS: In this cross-sectional study, 773 CBCT samples were retrieved from archives of a private oral and maxillofacial radiology center. Any findings that were not related to the reason of CBCT request was re...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کامل