Impact of dynamic computed tomographic angiography on endograft sizing for endovascular aneurysm repair.

نویسندگان

  • Jillis A Pol
  • Maarten Truijers
  • J Adam van der Vliet
  • Mark F Fillinger
  • Steven P Marra
  • W Klaas Jan Renema
  • Luuk J Oostveen
  • Leo J Schultze Kool
  • Jan D Blankensteijn
چکیده

PURPOSE To quantify dynamic changes in aortoiliac dimensions using dynamic electrocardiographically (ECG)-gated computed tomographic angiography (CTA) and to investigate any potential impact on preoperative endograft sizing in relation to observer variability. METHODS Dynamic ECG-gated CTA was performed in 18 patients with abdominal aortic aneurysms. Postprocessing resulted in 11 datasets per patient: 1 static CTA and 10 dynamic CTA series. Vessel diameter, length, and angulation were measured for all phases of the cardiac cycle. The differences between diastolic and systolic aneurysm dimensions were analyzed for significance using paired t tests. To assess intraobserver variability, 20 randomly selected datasets were analyzed twice. Intraobserver repeatability coefficients (RC) were calculated using Bland-Altman analysis. RESULTS Mean aortic diameter at the proximal neck was 21.4+/-3.0 mm at diastole and 23.2+/-2.9 mm at systole, a mean increase of 1.8+/-0.4 mm (8.5%, p<0.01). The RC for the aortic diameter at the level of the proximal aneurysm neck was 1.9 mm (8.9%). At the distal sealing zones, the mean increase in diameter was 1.7+/-0.3 mm (14.1%, p<0.01) for the right and 1.8+/-0.5 mm (14.2%, p<0.01) for the left common iliac artery (CIA). At both distal sealing zones, the mean increase in CIA diameter exceeded the RC (10.0% for the right CIA and 12.6% for the left CIA). CONCLUSION The observed changes in aneurysm dimension during the cardiac cycle are small and in the range of intraobserver variability, so dynamic changes in proximal aneurysm neck diameter and aneurysm length likely have little impact on preoperative endograft selection. However, changes in diameter at the distal sealing zones may be relevant to sizing, so distal oversizing of up to 20% should be considered to prevent distal type I endoleak.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Hypovolemia on Aortic Dimensions

A ruptured thoracic aorta is a rare but lifethreatening condition requiring immediate intervention. Possible causes of a ruptured thoracic aorta are ruptured descending thoracic aneurysms, acute type B aortic dissections, penetrating aortic ulcers, and traumatic thoracic aortic injuries (TTAI). Thoracic endovascular aortic repair (TEVAR) offers an effective treatment for these acute thoracic ao...

متن کامل

Open versus endovascular AAA repair in patients who are morphological candidates for endovascular treatment.

PURPOSE To compare the outcomes of open versus endovascular repair of abdominal aortic aneurysm (AAA) in a cohort of patients who fulfill morphological criteria for endovascular repair. METHODS A retrospective review of 229 consecutive AAA patients treated over a 3-year period identified 149 patients who were candidates for endovascular repair based on preoperative computed tomography and ang...

متن کامل

Detection of endograft fractures with multidetector row computed tomography.

Delayed endograft metallic strut failures detected in vivo with multidetector row computed tomography (MDCT) are reported in two patients who underwent endovascular abdominal aortic aneurysm repair with AneuRx and Talent endografts. In both instances, nitinol fractures were associated with proximal migration and type I endoleak. In both cases, the metallic strut fractures were detected with tra...

متن کامل

Treatment of Abdominal Aortic Endograft Infolding

Aortic endograft infolding is considered a rare endograft related complication and is mostly reported after deployment in the thoracic aorta. We report a case of early abdominal endograft infolding with luminal obliteration and acute bilateral limb ischemia after endovascular treatment of a common iliac aneurysm. Even though completion Computed Tomography (CT) angiography, three days prior, rev...

متن کامل

Use of spiral computed tomographic angiography in monitoring abdominal aortic aneurysms after transfemoral endovascular repair.

Transfemoral endovascular repair of abdominal aortic aneurysms has proved to be technically feasible in a selected group of patients. However, long-term efficacy has not been proved. Graft performance after implantation can be monitored by a single imaging technique: spiral computed tomographic angiography. With this technique, the parameters for continuing clinical success of the procedure-gra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2009