Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methods

نویسندگان

  • Filippo Molinari
  • Kristen M. Meiburger
  • Luca Saba
  • U. Rajendra Acharya
  • Giuseppe Ledda
  • Guang Zeng
  • Sin Yee Stella Ho
  • Anil T. Ahuja
  • Suzanne C. Ho
  • Andrew Nicolaides
  • Jasjit S. Suri
چکیده

Automated and high performance carotid intima-media thickness (IMT) measurement is gaining increasing importance in clinical practice to assess the cardiovascular risk of patients. In this paper, we compare four fully automated IMT measurement techniques (CALEX, CAMES, CARES and CAUDLES) and one semi-automated technique (FOAM). We present our experience using these algorithms, whose lumen-intima and media-adventitia border estimation use different methods that can be: (a) edge-based; (b) training-based; (c) feature-based; or (d) directional Edge-Flow based. Our database (DB) consisted of 665 images that represented a multi-ethnic group and was acquired using four OEM scanners. The performance evaluation protocol adopted error measures, reproducibility measures, and Figure of Merit (FoM). FOAM showed the best performance, with an IMT bias equal to 0.025±0.225mm, and a FoM equal to 96.6%. Among the four automated methods, CARES showed the best results with a bias of 0.032±0.279mm, and a FoM to 95.6%, which was statistically comparable to that of FOAM performance in terms of accuracy and reproducibility. This is the first time that completely automated and user-driven techniques have been compared on a multi-ethnic dataset, acquired using multiple original equipment manufacturer (OEM) machines with different gain settings, representing normal and pathologic cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Method for Carotid Artry Recognition Using Ultrasound B-mode Scans

The aim of this paper is to describe a novel and completely automated technique for carotid artery (CA) recognition, far (distal) wall segmentation, and intimamedia thickness (IMT) measurement, which is a strong clinical tool for risk assessment for cardiovascular diseases. The architecture of completely automated multiresolution edge snapper (CAMES) consists of the following two stages: 1) aut...

متن کامل

Face Detection with methods based on color by using Artificial Neural Network

The face Detection methodsis used in order to provide security. The mentioned methods problems are that it cannot be categorized because of the great differences and varieties in the face of individuals. In this paper, face Detection methods has been presented for overcoming upon these problems based on skin color datum. The researcher gathered a face database of 30 individuals consisting of ov...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Reducing Retrieval Time in Automated Storage and Retrieval System with a Gravitational Conveyor Based on Multi-Agent Systems

The main objective of this study is to reduce the retrieval time of a list of products by choosing the best combination of storage and retrieval rules at any time. This is why we start by implementing some storage rules in an Automated Storage/Retrieval System (Automated Storage and Retrieval System: AS/RS) fitted with a gravity conveyor while some of these rules are dedicated to storage and ot...

متن کامل

Hybrid Techniques of Multi-Criteria Decision-Making for Location of Automated Teller Machines (ATMs): Shahr Bank Branches in Tehran, 1st District Municipality

Location is an important factor in the activity of economic enterprises. Owing to the importance, location-based sciencesought/seeks to provide the methods in order to determine and select the optimal location in the activities of enterprises. Enterprises seek to use scientific methods to maximize the services and efficiency and minimize the costs. Suitable location plays an important role in m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 108 3  شماره 

صفحات  -

تاریخ انتشار 2012