Apical aortic valve implantation in a patient with a mechanical valve prosthesis in mitral position.

نویسندگان

  • Josep Rodés-Cabau
  • Eric Dumont
  • Santiago Miró
  • Daniel Doyle
  • Robert De Larochellière
  • Marie-Annick Clavel
  • Jacques Villeneuve
  • Sebastien Bergeron
  • Mario Senechal
  • Philippe Pibarot
چکیده

A 67-year-old man diagnosed with severe aortic stenosis was admitted to our institution with pulmonary edema. The patient had a history of severe pulmonary fibrosis (total lung capacity, 57% of predicted value; diffusing capacity for carbon monoxide, 33% of predicted value) and had undergone coronary bypass grafting and mitral valve replacement with a St Jude mechanical valve (St Jude Medical, St Paul, Minn) 18 years ago. Doppler echocardiography showed a mean aortic gradient of 36 mm Hg, an aortic valve area of 0.50 cm, and a left ventricular ejection fraction of 45%. Although the mean predicted operative mortality by the Society of Thoracic Surgeons score was 7.5%, the patient was considered at too high risk for surgical aortic valve replacement because of his pulmonary condition, and he was then evaluated for percutaneous aortic valve implantation (PAVI). Transesophageal echocardiography (TEE) showed an aortic annulus of 23 mm as well as proximity between the mitral prosthesis and the aortic annulus (Figure 1A). Contrast computed tomography showed the presence of moderate stenosis and severe calcification of both iliofemoral arteries precluding transfemoral PAVI, and the patient was then proposed for transapical PAVI. The procedure was performed in the operating room under TEE and fluoroscopy guidance by a team of cardiac surgeons and interventional cardiologists using the techniques extensively described in previous reports.1–3 Concerns about the interference of the mitral mechanical prosthesis with the expansion of the new aortic valve and the potential increased risk of valve embolization led us to perform balloon valvuloplasty by transfemoral approach with a 23-mm balloon just before thoracothomy. After valvuloplasty that showed the stability and complete expansion of the balloon, a left anterior minithoracotomy was performed to expose the apex, and 2 large pursestrings with pledgets were placed at the left ventricular apex. After puncturing the apex, a stiff guidewire was positioned in the descending aorta, and a 26F sheath was

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Successful Transfemoral Edwards Sapien Aortic Valve Implantation in a Patient with Previous Mitral Valve Replacement

Transcatheter aortic valve implantation (TAVI) is a new method for patients with severe aortic stenosis at high surgical risk, such as previous cardiac surgery. The presence of mechanical mitral prosthesis might complicate TAVI because of possible interference between the both prosthesis. Some reports have already demonstrated the feasibility of TAVI in such patients. We report our experience w...

متن کامل

Portico Transcatheter Implantation in a Patient with Mechanical Mitral Valve

Transcatheter aortic valves implantation (TAVI) is a valid treatment for high-risk surgical candidates with symptomatic severe aortic stenosis; the safety and effectiveness of TAVI have been demonstrated in numerous clinical studies, national registries and randomized trials. Nevertheless, from this cohort of patients have been often excluded patients with prior mitral valve surgery because con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 1 3  شماره 

صفحات  -

تاریخ انتشار 2008