Cerebral arteriovenous malformations: diagnostic value of echo-enhanced transcranial Doppler sonography compared with angiography.

نویسندگان

  • M M Uggowitzer
  • C Kugler
  • M Riccabona
  • G E Klein
  • K Leber
  • J Simbrunner
  • F Quehenberger
چکیده

BACKGROUND AND PURPOSE The purpose of our study was to examine the clinical value of echo-enhanced transcranial power Doppler sonography (EE-TCD), including it ability to assess hemodynamic parameters of the intracranial vasculature, in patients with suspected cerebral arteriovenous malformations (AVMs) and to compare this method with angiography. METHODS Sixteen patients with suspected cerebral AVMs were examined with EE-TCD and angiography. As an echo-enhancing agent, SHU 508A (Levovist) was administered intravenously by bolus injection in nine patients and by continuous infusion in seven. Sonograms were reviewed without knowledge of other imaging results and were correlated with angiographic findings. RESULTS Angiography showed AVMs in 12 of 16 patients. Eleven lesions were located in the anterior or middle fossa and one was in the posterior fossa. EE-TCD was slightly less sensitive in the detection of AVMs (92%, 11/12 lesions), since in one patient the lacking acoustic window did not allow a transcranial examination. EE-TCD slightly underestimated AVM size compared with angiographic findings but showed feeding arteries with sufficient acoustic properties. In seven patients (58%), angiography revealed a coincidental blood supply from another intracranial or extracranial vessel, which was missed by EE-TCD in all cases. Assessment of peak systolic velocities and resistive indexes resulted in a higher (mean, 191.1 cm/s) and a lower (mean, 45.7%) value, respectively, in the feeding arteries as compared with the contralateral arteries (mean, 101.8 cm/s and 55.6%, respectively). Side-to-side differences were significantly higher in patients with AVMs than in those without a malformation. Signal enhancement was markedly longer with continuous infusion (mean, 520 seconds +/- 28.2) than with bolus injection (mean, 145 seconds +/- 10.5) of the contrast agent. CONCLUSION In our limited study group, EE-TCD was a sensitive method for the detection of AVMs, and Levovist proved to be a safe and effective echo-enhancing substance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine

Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...

متن کامل

Evaluation of cerebrovascular disease by combined extracranial and transcranial Doppler sonography. Experience in 1,039 patients.

Results from 1,039 combined cervical and transcranial Doppler examinations are reported. Satisfactory transcranial signals were not found in 2.7% of the cases. Compared with angiography, the accuracy of transcranial criteria in assessing collateral flow over the circle of Willis was 94 and 88% for anterior and posterior circulation, respectively. The method also appeared very promising for dete...

متن کامل

Dural arteriovenous fistula after cerebral sinus thrombosis: a case study of serial venous transcranial color-coded sonography.

ural sinus thrombosis has been proposed as the primary event in the formation of a dural arteriovenous fistula (DAVF).1–4 However, the temporal course of development of a DAVF after cerebral sinus thrombosis has rarely been shown clinically. Venous angiography is a sensitive method for evaluating sinus thrombosis.5 However, the invasiveness of venous angiography limits its value in the follow-u...

متن کامل

Doppler Sonography and 3D CT Angiography of Acquired Uterine Arteriovenous Malformations (AVMs): Report of Two Cases.

Uterine Arteriovenous Malformations (AVMs) are rare but life threatening causes of abnormal vaginal bleeding. Accurate clinical and radiological diagnosis is essential because uterine instrumentation that is often used for management of other sources of abnormal bleeding, can lead to massive hemorrhage. Timely diagnosis and early proper treatment can markedly reduce the associated disease morta...

متن کامل

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 1999