Prosthetic replacement of the ocular surface ecosystem: impact at 5 years

نویسندگان

  • Joshua S Agranat
  • Nicole R Kitos
  • Deborah S Jacobs
چکیده

BACKGROUND/AIMS To determine the impact of prosthetic replacement of the ocular surface ecosystem (PROSE) treatment at 5 years. METHODS Retrospective review of clinical, manufacturing and quality databases at the Boston Foundation for Sight. RESULTS 121 patients who completed treatment and had 5-year follow-up data were identified from a cohort of patients (n=199) seen in consultation for PROSE treatment from January 2008 to June 2008. Mean age was 52 years, M:F=56:65. The primary indication for treatment was ocular surface disease (OSD) in 64 patients and distorted corneal surface in 57 patients. At 5 years, continued device wear was confirmed in 89/121 (73.6%) patients. Discontinuation of wear was confirmed in 32/121 (26.4%). There was an increased likelihood of continued device wear at 5 years in patients with distorted cornea (84%) compared with those with OSD (64%), (p=0.0121, χ(2)). National Eye Institute Visual Function Questionnaire (NEI VFQ-25) composite score increased for patients wearing PROSE devices at 6 months (Δ=+23 points, mean=82, p<0.001, two-tailed t test) with no significant decline among those still wearing a device at 5 years (Δ=-4 points, mean=78, p=0.22, two-tailed t test). At 5 years, those wearing (mean=78) had a higher NEI VFQ-25 than those not wearing (mean=70, p=0.029, two-tailed t test). CONCLUSIONS PROSE treatment offers continued benefit, as defined by improved visual function and continued device wear at 5 years, in patients with complex corneal disease. Patients with distorted cornea have a higher rate of continued wear at 5 years than patients with OSD, although this is not true among all subgroups within OSD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of chronic corneal opacity in ocular surface disease with prosthetic replacement of the ocular surface ecosystem (PROSE) treatment

Purpose To demonstrate clearing of chronic corneal opacities and improvement of visual acuity with the use of BostonSight prosthetic replacement of the ocular surface ecosystem (PROSE) treatment in ocular surface disease. Observations We undertook retrospective analysis of the medical records of a series of patients who underwent PROSE treatment from August 2006 to December 2014. Patients wer...

متن کامل

Comparison of hyaluronic acid-containing topical eye drops with carbomer-based topical ocular gel as a tear replacement in canine keratoconjunctivitis sicca: A prospective study in twenty five dogs

The aim of this study was to evaluate the efficacy of a hyaluronic acid containing eye drop in ameliorating ocular surface pathology and discomfort in canine keratoconjunctivitis sicca (KCS). Twenty five dogs with KCS treated with a topical carbomer (CA)-based tear replacement gel were moved to treatment with a hyaluronic acid (HA)-containing tear replacement eye drop. Dogs were subject to a fu...

متن کامل

Utility of Prosthetic Replacement of the Ocular Surface Ecosystem Treatment in the Management of Patients with Refractory Intrinsic Evaporative Dry Eye Disease

Background: Dry eye disease is a multifactorial disease whose pathogenic mechanisms have not been investigated rigorously. The objective of this study was to evaluate the utility of Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) treatment in the management of patients with intrinsic evaporative dry eye refractory to conventional therapies. Design: A retrospective clinical cohort...

متن کامل

Visual performance with changes in eccentricity in PROSE device: a case report.

This case report describes the variations in visual performance of a subject with moderate keratoconus with changes in front surface eccentricities (FSEs) of PROSE (Prosthetic Replacement of Ocular Surface Ecosystem). PROSE device of 0.6 FSE provided maximum visual improvement and reduction in Higher Order Aberrations (HOAs) compared to 0, 0.3 and 0.8 FSEs in this clinical condition.

متن کامل

Prevention of Periprosthetic Joint Infection

Prosthetic joint infection (PJI) is a calamitous complication with high morbidity and substantial cost. The reported incidence is low but it is probably underestimated due to the difficulty in diagnosis. PJI has challenged the orthopaedic community for several years and despite all the advances in this field, it is still a real concern with immense impact on patients, and the healthcare system....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 100  شماره 

صفحات  -

تاریخ انتشار 2016